MERLIN LEGEND Communications System Release 5.0
System Manager’s Guide  
555-650-118  
Issue 1
June 1997
Managing the System 
Page 6-89
Adding a CTI Link 
6
The CTI link can be programmed before the CTI link hardware is plugged 
into a port on a 008 MLX or a 408 MLX module. The port you select for the 
CTI link should be planned with the following conditions in mind:
— When checking the system Extension Report or planning form (2a, 
System Numbering: Extension Jacks) to locate an available extension, 
make sure that both the main extension number (for example, extension 
11 in a 2-digit dial plan) and the adjunct extension number (for example, 
extension 711 in a 2-digit dial plan) are available. Check the report for 
2B data programming.
— If you program a CTI link for a jack that is already programmed for 2B 
data, the CTI programming renders the 2B data programming 
nonfunctional, and a 2B data device that you later connect to the jack 
will not function as such.
— Do not use the first or fifth extension jack, reserved for operator 
positions or programming, for the CTI link. System programming and 
operator extensions cannot be programmed as CTI link extensions.
— Make sure that the port does not have a telephone, video system, 
communications equipment, or other device connected to it. Do this 
before attempting to program the CTI link.
The firmware for the MLX module must be of vintage earlier or later than 
29. If you attempt to program a CTI link on a module of firmware vintage 
29, the system halts the process.
If the CTI link extension is programmed as a member of a calling or coverage 
group, this programming is removed automatically when the port is specified for a 
CTI link. If there are Cover buttons for this extension at other extensions in the 
system, the system informs you and asks you to remove this programming. Check 
the system Extension Report (see 
 for information) 
or relevant system planning forms for extensions and groups (for example, Form 
4d, MLX Telephone and Form 7c, Group Coverage) to identify the extensions 
where the programming should be removed.
Before you program a CTI link, you must busy-out the slot where the module with 
the CTI link jack is located. After programming is complete, you must restore the 
slot and return it to service. If you plan to use the console for programming, the 
programming extension must 
not
 be on the same module as the planned CTI link. 
If your system includes only one MLX extension module, you must use SPM 
(System Programming and Maintenance) software to perform the programming.
CAUTION:
!
The Maintenance procedures outlined below are normally reserved for 
Lucent Technologies technicians only. Do not use the Maintenance menu 
except as outlined below, unless you are instructed to do so by a Lucent 
Technologies representative.