Parameters
Parameter
Description
controller
The identifier letter of the RAID controller module 
that has the iSCSI host ports. Valid RAID controller 
module identifier values are 0 or 1, where, 0 is the 
RAID controller module in slot 0, and 1 is the RAID 
controller module in slot 1.
iscsi-host-port
The identifier of the port on the storage array on 
which you want to refresh the DHCP parameters. 
Enclose the iSCSI host port name in square 
brackets ([ ]).
NOTE: This operation ends the iSCSI connections for the portal and brings down the portal 
temporarily.
Start Physical Disk Blink
Description
This command blinks a physical disk by turning on an indicator light on the physical disk. Run the stop 
physicalDisk blink command to turn off the indicator light on the physical disk.
Syntax
start physicalDisk [enclosureID,slotID] blink
Parameters
Parameter
Description
physicalDisk
The location of the physical disk that you want to 
find. For high-capacity expansion enclosures, 
specify the enclosure ID value and the slot ID value 
of the physical disk that you want to revive. 
Enclosure ID values are 0 to 99. Slot ID values are 
0 to 31. Enclose the enclosure ID value and the slot 
ID value in square brackets ([ ]).
Start Physical Disk Channel Blink
Description
This command identifies the expansion enclosures that are connected to a specific physical disk port by 
turning on the indicator lights for the expansion enclosure that is connected to the physical disk port. Use 
the stop physicalDiskChannel blink command to turn off the indicator lights on the expansion 
enclosure.