Furuno FI-504 Manuel D’Utilisation
FI-504 MULTI
E7269S01A
SP-1
SPECIFICATIONS OF
FI-504 MULTI
1 GENERAL
1.1 Display
Segment
LCD
1.2 Display Content
Depth, speed, wind speed, wind angle,
timer, environmental information (water
temperature, air temperature, air
pressure, dewpoint, wind chill
temperature), rudder angle
pressure, dewpoint, wind chill
temperature), rudder angle
1.3 I/O Port
NMEA 2000, 2 ports
2
JUNCTION BOX (OPTION)
2.1 No. of I/O ports
NMEA 2000 Device
6 ports
NMEA 2000 Backbone
2 ports
3 POWER SUPPLY AND POWER CONSUMPTION
3.1 Display Unit
12 VDC, less than 0.1 A
3.2 Junction
Box
12 VDC, less than 1 A, max. 2A connectable
4 ENVIRONMENTAL
CONDITIONS
4.1 Useable Temperature Range
-15°C - +55°C
4.2 Relative Humidity
Less than 95% (+40°C)
4.3 Waterproofing
Display
Unit
IP56
Junction
Box
IPX0
4.4 Vibration
- 2 Hz-5 Hz and up to 13.2 Hz with an
excursion of ±1 mm ±10% (7 m/s
2
maximum acceleration at 13.2 Hz);
- above 13.2 Hz and up to 100 Hz with a
constant maximum acceleration of 7 m/s
2
5 COATING
COLOR
5.1 Display
Unit
N2.5
5.2 Junction
Box
N2.5