Chapter 5: Serial Port, Host, Device, and User Configuration 
 
                                                724-746-5500   |   blackbox.com                                                       
39
• Select the connection type for the new connection (Serial, Network Host, UPS, or RPC) and then select the specific connection from the  
   presented list of configured unallocated hosts/ports/outlets. 
 
To add a new network-connected Managed Device: 
 
The Administrator adds a new network-connected Managed Device using Add Host on the Serial & Network:  Network Host menu. This 
automatically creates a corresponding new Managed Device (as covered in Section 5.4—Network Hosts). 
 
When adding a new network-connected RPC or UPS power device, you set up a Network Host, designate it as RPC or UPS, then go to RPC 
Connections (or UPS Connections) to configure the relevant connection. A corresponding new Managed Device (with the same Name /Description 
as the RPC/UPS Host) is not created until you complete this connection step (refer Chapter 8—Power Management). 
 
NOTE:  
The outlet names on this newly created PDU will by default be “Outlet 1” and “Outlet 2.” When you connect a particular Managed 
Device (that draws power from the outlet), then the outlet will take the powered Managed Device’s name. 
 
To add a new serially connected Managed Device: 
 
• Configure the serial port using the Serial & Network: Serial Port menu (refer to Section 5.1—Configure Serial Port). 
 
• Select Serial & Network: Managed Devices and click Add Device. 
 
• Enter a Device Name and Description for the Managed Device. 
 
 
 
Figure 5-21. Add a new device screen. 
 
• Click Add Connection and select Serial and the Port that connects to the Managed Device. 
 
• To add a UPS/RPC power connection or network connection or another serial connection, click Add Connection. 
 
• Click Apply. 
 
NOTE:  
To set up a new serially connected RPC UPS or EMD device, configure the serial port, designate it as a Device, then enter a Name and 
Description for that device in the Serial & Network: RPC Connections (or UPS Connections or Environmental). When applied, this will 
automatically create a corresponding new Managed Device with the same Name /Description as the RPC/UPS Host (refer to Chapter 8—
Power Management)
 
All the outlet names on the PDU will by default be “Outlet 1” and “Outlet 2.” When you connect a particular Managed Device (that  
draws power from the outlet), then the outlet will take the name of the powered Managed Device.