3. INSTALLATION 
 30
3.5  Magnetron Heater Voltage 
Magnetron heater voltage is formed at the 
MD Board of the antenna unit and is 
preadjusted at the factory. Therefore, no 
adjustment is required. However, verify the 
voltage as below. 
WARNING
ELECTRICAL SHOCK HAZARD
Do not open the equipment.
DO NOT attempt the
procedure below unless 
totally familiar with electrical
circuits.
 
1.  Open the antenna cover and open the 
shield plate. 
2.  Turn on the power. 
DO NOT transmit. 
3.  Connect a multimeter, set to 10 VDC 
range, between #6 (+) and #4 (-) of test 
point TP804 on the MD Board. 
TP804
VR801
 
MD board 
4.  Confirm that the multimeter shows 8.0 V 
±0.1 V. If it does not, adjust potentiometer 
VR801 on the MD Board.   
5.  Turn off the power. 
6.  Fasten the shield plate. 
7.  Close the antenna cover.