Jenn-Air 720-0061-LP Manuel D’Utilisation

Page de 29
 
 
 
 
 
GENERAL 
Although all gas connections on the grill are leak 
tested at the factory prior to shipment, a complete 
gas tightness check must be performed at the 
installation site due to possible mishandling in 
shipment, or excessive pressure unknowingly being 
applied to the unit. Periodically check the whole  
 
system for leaks following the procedures listed 
below. If the smell of gas is detected at anytime you 
should immediately check the entire system for 
leaks. 
 
 
BEFORE TESTING
 
Make sure that all packing material is removed from 
the grill including the burner tie-down straps. 
 
DO NOT SMOKE WHILE LEAK TESTING. 
 
NEVER LEAK TEST WITH AN OPEN FLAME. 
 
Make a soap solution of one part liquid detergent 
and one part water. You will need a spray bottle, 
brush, or rag to apply the solution to the fittings. For 
the initial leak test, make sure the L.P. cylinder is 
full. 
 
TO TEST 
Make sure all control valves are in the “OFF” 
position. Turn the gas supply on. Check all 
connections from the L.P. cylinder up to and 
including the connection to the manifold pipe 
assembly (the pipe that goes to the burners). Soap 
bubbles will appear where a leak is present. If a 
leak is present, immediately turn off the gas supply, 
tighten any leaking fittings, turn gas on, and 
recheck. Should the gas continue to leak from any 
or all of the fittings, turn off the gas supply, and 
contact our customer service at 1-800-554-5799. 
 
Only those parts recommended by the 
manufacturer should be used on the grill. 
Substitution will void the warranty. Do not use the 
grill until all connections have been checked and do 
not leak. 
 
Gas flow check: 
 
Each grill burner is tested and adjusted at the 
factory prior to shipment; however, variations in the  
 
 
 
LEAK TESTING
local gas supply may make it necessary to adjust 
the burners. The flames of the burners should be 
visually checked. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Adjustment Bolt 
Locking Nut
 
 
Flames should be blue and stable with no yellow 
tips, excessive noise or lifting. If you have any 
questions regarding flame stability, please call 
customer service at  
1-800-554-5799. 
 
ALWAYS CHECK FOR LEAKS AFTER EVERY 
LP TANK CHANGE 
 
Check all gas supply fittings for leaks before 
each use. It is handy to keep a spray bottle of 
soapy water near the shut-off valve of the gas 
supply line. Spray all the fittings. Bubbles 
indicate leaks. 
 
Disconnected L.P. cylinders must have 
threaded valve plugs tightly installed, and must 
not be stored in a building, garage or any other 
enclosed area. 
 
The gas must be turned off at the supply 
cylinder when the unit is not in use. 
 
If the appliance is stored indoors the cylinder 
must be disconnected and removed from the 
appliance. Cylinders must be stored outdoors in 
a well-ventilated area out of the reach of 
children. 
12