Desa M42EP Manuel D’Utilisation

Page de 32
www.desatech.com
108796-01K
19
TO TURN OFF GAS 
TO APPLIANCE
1.  Turn off the wall switch.
2.  Turn off all electric power to the appliance 
if service is to be performed.
3.  Fully open glass doors if installed.
4.  Remove  front  hearth  brick  and  control 
access panel.
5.  Turn gas control knob clockwise 
 
to “OFF”. Do not force.
6.  Replace  front  refractory  brick  access 
panel.
7.  Fully close glass doors if installed.
OPTIONAL REMOTE
OPERATION
Note:
 The WRC receiver and hand-held re-
mote control kit must be purchased separately 
(see Accessories, page 29). Follow installation 
instructions on page 10.
1.  Turn equipment shutoff valve to ON posi-
tion. You can now turn the burner on and 
off with the hand-held remote control unit. 
 
IMPORTANT:
 Be sure to press the ON/OFF 
buttons on the hand-held remote control 
unit for up to 3 seconds to assure proper 
operation.
2.  Press  the  ON/OFF  button  to  turn  the 
burner on and off.
OPERATING FIREPLACE
Continued
Figure 38 - Pilot
Sensing 
Rod
Pilot 
Burner
Ignitor
Pilot 
Burner
Ignitor/
Sensor
INSPECTING BURNERS
Check pilot flame pattern and burner flame pat-
terns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper 
flame. Alterations may have occurred during ship-
ping and handling. The pilot is located on the back 
right hand side of the burner.
The flame must envelope 1/4" of top of the ignitor/
sensor and grounding stem. 
If your pilot assembly does not meet these re-
quirements:
•  Turn  the  adjustment  screw  marked  PILOT 
clockwise to decrease or counterclockwise to 
increase the flame to proper size (see Figure 37, 
page 19). Do not remove the adjustment screw.
•  see Troubleshooting, page 22
BURNER FLAME PATTERN
Burner flames will be steady; not lifting or floating. 
Flames should go up through the middle of logset. 
Flames should not "spill" to the edges of the pan 
or sides of the logset.
Figure 40 shows a typical flame pattern. If burner 
flame pattern differs from that described:
•  turn appliance off (see To Turn Off Gas to Ap-
pliance
•  see Troubleshooting, page 22
Figure 39 - Correct Pilot Flame Pattern
Figure 40 - Typical Flame Pattern
Sensing 
Rod