16 
For Horizontal Termination 
 
Figure 16: Horizontal Vent Termination Location 
A=12 inches 
Clearance above the grade, a veranda, porch, deck, or balcony 
B=12 inches 
Clearance to window or door that may be opened. 
 
C=12 inches 
Clearance to permanently closed window. 
 
D*=18 inches 
Vertical clearance to ventilated soffit located above the terminal within a horizontal 
distance of 2 feet from the centerline of the terminal.  
 
E*=18 inches 
Clearance to unventilated soffits. 
 
F=9 inches 
Clearance to an outside corner. 
 
G=6 inches 
Clearance to an inside corner. 
H=3 feet 
Not to be installed above a gas meter/regulator assembly within 3 feet horizontally from 
the centerline of the regulator. 
I=6 feet 
Clearance to service regulator vent outlet. 
J=12 inches 
Clearance to non-mechanical air supply inlet to building or the combustion air inlet to 
any other appliance. 
K=6 feet 
Clearance to a mechanical air supply inlet 
L**=7 feet 
Clearance above a paved sidewalk paved driveway located on public property. 
M***=12 inches  Clearance under veranda, porch, deck, or balcony. 
 
 
 
 
As specified in CGA B149 Installation Codes. Note: Local codes or regulations may 
require different clearances. 
 
30” minimum for vinyl clad soffits 
 
** 
A vent must not terminate directly above a sidewalk or paved driveway, which is 
located between two single-family dwellings and serves both dwellings. 
 
*** 
Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 
sides beneath the floor.