5. ELECTRICAL REQUIREMENTS
 
 
The ACCENT 25 will operate without electrical power.  This model has a Millivolt gas control which uses the pilot flame to 
generate enough electricity to operate the main burners. The appliance when equipped with blower must be electrically 
connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 
CANADIAN ELECTRICAL CODE Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, OR THE NATIONAL 
ELECTRICAL CODE ANSI / NFPA 70 in the U.S. 
 
 
WARNING
:  Electrical 
grounding instructions. This 
appliance is equipped with a 
three-prong (grounding) plug for 
your protection against shock 
hazard, and should be plugged 
directly into a properly 
grounded three-prong outlet. 
 
DO NOT cut or remove the 
grounding prong from this plug. 
 
REMOVING / INSTALLING THE BLOWER  
 
1.  Turn the unit off, open the door and remove the log set. Remove 
brick panel(s) (see Removing and Installing Brick Panels).  Remove 
the burner tray assembly by removing the two (2) screws on either 
side of the tray.  Pull tray up at the back and lift out.  
 
2.  Disconnect the gas line to the nipple.  Remove the three (3) screws 
holding the burner control tray to the back firewall.  Lift tray up on left 
side and pull out. 
 
3. 
Pull blower towards you.  Disconnect wires from the blower and 
remove.
  
 
4.  To re-install perform the preceding steps in reverse. 
CAUTION: Label all wires prior 
to disconnection when servicing 
controls.  Wiring errors can 
cause improper and dangerous 
operation.  Verify proper 
operation after servicing 
 
INSTALLING REMOTE THERMOSTAT OR WALL SWITCH  
RECOMMENDED WIRE SIZE 
for thermostat installation: 18 gauge, 2 wire solid core, Low Voltage wire. (Bell wire) 
 
1. 
Install the 18 Gauge wire supplied to the two terminals on the thermostat or remote wall switch. 
 
2. 
Connect the other end of the wire to the gas valve using the two outside terminals on the front of the gas valve. 
Use the terminals marked (TP/TH and TH). 
 
RECOMMENDED MAXIMUM LEAD LENGTH (TWO WIRE) 
WHEN USING WALL THERMOSTAT 
WIRE SIZE MAXIMUM 
LENGTH 
14 GAUGE 
100 FEET 
16 GAUGE 
64 FEET 
18 GAUGE 
40 FEET 
20 GAUGE 
18 FEET 
 
 