Q-Logic 8100 Manuel D’Utilisation

Page de 366
10–Converged Network Adapter Interactive Commands
CNA FCoE Configuration
SN0054667-00  C
10-31
Bind Target(s)
1. CNA FCoE Configuration2. Target Persistent Binding2. Bind Target(s)
From the Target Persistent Binding Menu, select the Bind Target(s) option to bind 
target devices. For example:
    Target Persistent Binding Menu
=======================================================
CNA           : 0 Port: 1
SN            : AFE1028C03899
ENode MacAddr : 00:0E:1E:04:95:EB
CNA Model     : QLE8242
CNA Desc.     : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE)
FW Version    : 4.07.31
WWPN          : 21-00-00-0E-1E-04-95-EB
WWNN          : 20-00-00-0E-1E-04-95-EB
Link          : Online
=======================================================
    1:  Disk
           Vendor                       : DGC
           Product ID                   : RAID 0
           Port Name                    : 50-06-01-60-41-E0-63-25
           Port ID                      : 11-00-EF
           Bind                         : No
           Target ID                    :
    2:  Device
           Vendor                       : N/A
           Product ID                   : N/A
           Port Name                    : 20-70-00-C0-FF-D8-32-7F
           Port ID                      : 00-00-00
           Bind                         : Yes
           Target ID                    : 0
    3:  All Target(s)
        (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit)
        Please Enter Selection: 1
Enter Target ID: 1
    Target Persistent Binding - FC Port Configuration
    1:  Select More
    2:  Commit Changes
    3:  Cancel