Leica 1000Z01 Manuel D’Utilisation
110
TPS-System 1000 Programs-2.3.1en
© Leica
IV
EL
AH
OH
BS
SM
AS
FS
BL
RH
Start the "Configuration Editor" from the "MEASURE
REMOTE POINT" dialog.
REMOTE POINT" dialog.
REMHT\ CONFIGURATION
14:03
INFO
DFLT
YES
F1
F2
F3
F4
F5
F6
HELP
MC
User Displ
:
NO
Hor.Pos.Tol
:
0.200
m
Rec
∆
H WI37
:
OFF
The "Configuration Editor" sets parameters for further
program operations:
program operations:
User Disp
: Set to YES, the display defined in the
"MEAS" application will be used.
If set to NO, the "REMOTE
HEIGHT" default display applies.
If set to NO, the "REMOTE
HEIGHT" default display applies.
Hor.Pos.Tol
: Horizontal distance tolerance that
valid point measurements cannot
exceed.
exceed.
Rec
∆∆∆∆∆
H WI37:Set to ON, the program will store
∆
height difference as record WI37 in
the database.
the database.
Configuration
Displays date and version of the running application.
Reset configuration parameters to their default values.
Default settings are shown in dialog above.
Default settings are shown in dialog above.
Accept the current configuration and proceed to the
dialog "MEASURE BASE PT".
dialog "MEASURE BASE PT".