Leica 1000Z01 Manuel D’Utilisation

Page de 347
© Leica
TPS-System 1000 Programs-2.3.1en
301
IV
EL
AH
OH
BS
SM
AS
FS
BL
HB
KM
FB
SA
PZ
LB
TB
CO
RP
Log File
If "Log File" is set to "ON" the measurements and the
results are stored in the ASCII-file specified within the
"Configuration Editor". This file is created in the
directory LOG on the memory card. Subsequently, you
can read the memory card on your PC and obtain a hard
copy of the Log-file.
Data will always be appended to the specified Log-file.
The Log-file contains the following information:
Header
includes:
-  the program used,
- information about the instrument,
- the file to store the measurement
data,
- the date and the time.
Configuration
the name of the input files for:
- the Hz-alignment,
- the V-alignment and
- the cross section.
Measurement
- Instrument station with coordinates
and instrument height.
- Stakeout point with heigth offset,
- offset
1
 and height displacement
2
relative to centre line,
- comparison values from planning,
and associated differences.
1
This value results from
- the displacement of the zero point of the profile and
- the displacement taken from the transverse profile.
2
This value results from
- the displacement of the zero point of the profile and
- the displacement taken from the transverse profile
- the height displacement in the configuration.