The "Configuration Editor" sets parameters for further
program operations:
Hz Ori Acc
: Limit for the standard deviation of the
orientation. The orientation is
regarded as "error free", if the
computed standard deviation of the
orientation is within twice the entered
value.
Ht Acc TP
: Height accuracy of the target points.
The entered value, is used as an "a
priori" accuracy in the calculation.
The height is regarded as "error free",
if the computed standard deviation is
within twice the entered value.
Start the "Configuration Editor" from the "STATION
DATA