Leica 1000Z01 Manuel D’Utilisation

Page de 347
84
TPS-System 1000 Programs-2.3.1en
© Leica
IV
EL
AH
OH
BS
SM
AS
FS
σσσσσ
 Orient
: Standard deviation of the Orientation
Calc Scale
YES scale factor is calculated,
NO scale factor is not calculated
Scale
: The scale factor of the free station
calculation.
Note that the scale is not shown if
set to NO.
Set orientation and station coordinates on the
instrument. Note that this key will end the program.
Record the following results on the active recording
device:
WI 11
Station Point Number
WI 25
Orientation correction
WI 84
Station Easting
WI 85
Station Northing
WI 86
Station Elevation
WI 87
Last reflector height used
WI 88
Instrument Height
Sketch of the station and the reference points used.
Show the results of individual measurements on the
screen (see dialog "More Information").
Measure more points. The program will recall the
"TARGET POINT" dialog.
Select between the "Robust" method and the "Variati-
on" method
Exit the program.