9.  Machine Error Compensation 
9.2  Setting Compensation Data 
 
 
274 
(2) Incremental 
system 
The following figure (left) contains a machine position that is placed in the positive direction with 
respect to the reference point. Assume that feed from division n–1 to n (division interval) is 
executed. In this case‚ the following value is defined as the compensation amount: 
(Division interval – Actual movement distance) 
× 2 (Unit of output) 
The following figure (right) contains a machine position that is placed in the negative direction with 
respect to the reference point. Assume that feed from division point n+1 to n by the division interval 
is executed. In this case‚ the following value is defined as the compensation amount: 
(Division interval + Actual movement distance) 
× 2 (Unit of output) 
 
 
 
 
 
 
 
 
n: Division point compensation number
1: Division interval 
(Note)  The unit of output is used as the unit of setting. The actual unit of compensation pulses depends
on the compensation scale factor.
Unit 
: Unit of output
Range 
: –128 to 127