Mitsubishi Electronics C64 Manuel D’Utilisation

Page de 317
12.  Position Switch 
12.1  Outline of Function 
 
 
284 
12.  Position Switch 
12.1  Outline of Function 
The position switch (PSW) is used as an imaginary dog switch by assigning an axis name and 
coordinate values that indicate the imaginary dog position to be used instead of the dog switch on the 
machine axis. When the machine reaches the imaginary dog position, a signal is output to the PLC 
interface. This imaginary dog switch is called the position switch (PSW). 
 
No. 
Item 
Details 
Setting range (unit)
7500 Pcheck  High-speed 
switching of 
position switch 
Specify whether to perform position 
switch area checking at high speeds. 
0:  Does not perform position switch 
area checking at high speed (do it the 
same as before). 
1:  Performs position switch area 
checking at high speed. 
0/1 
75
∗1  <axis> 
Axis name 
Specify the name of the axis for which a 
position switch is provided. 
X, Y, Z, U, V, W, A, 
B, or C axis address
75
∗2  <dog1> Imaginary 
dog 
position 1 
When the machine enters the range 
between imaginary dog positions 1 and 
2, a signal is output to the PLC. 
−99999.999 
to 99999.999
(0.001mm)
75
∗3  <dog2> Imaginary 
dog 
position 2 
Part system 1 device X 660 
Part system 2 device Y 6E0 
 
75
∗4  <check>  Selection of area 
check method 
When position switch area checking at 
high speed is selected, specify the mode 
of area checking, i.e., whether to use the 
command type machine position or 
detector feedback position, for each 
position switch point. 
0:   Use the command type machine 
position as the machine position for 
position switch area checking. 
1:   Use the detector feedback position 
as the machine position for position 
switch area checking. 
(Note)  This parameter is valid only 
when 1 set in “#7500 Pcheck.” 
0/1