Mitsubishi Electronics C64 Manuel D’Utilisation
13. Indexing Axis Parameters
288
# Item
Details
Setting range
(unit)
26256 CURRENT LIMIT
Set current limit value when current limit value
command signal is ON.
command signal is ON.
0 to 100 (%)
26257 OFFSET
Set the indexing position compensation amount. -999.999 to
999.999
(mm)
(mm)
26258 OFFSET LIMIT
If the indexing position compensation amount
exceeds this value, the "index position offset MAX
reached" signal (M:Y18E, L:Y100) will be output.
exceeds this value, the "index position offset MAX
reached" signal (M:Y18E, L:Y100) will be output.
0 to 999.999
(mm)
(mm)
26259 DETECTION WIDTH
Set the tolerable width for outputting the
in-position signal when indexing is completed.
in-position signal when indexing is completed.
0 to 999.999
(mm)
(mm)
26260 CURRENT LIMIT 2
Set current limit value when current limit value
command 2 signal is ON.
command 2 signal is ON.
0 to 100 (%)
26261 CURRENT LIMIT 3
Set current limit value when current limit value
command 3 signal is ON.
command 3 signal is ON.
0 to 100 (%)