GTO R4854 01 Manuel D’Utilisation

Page de 40
14
  GTO 4000XLS Instruction Manual © 01.10.12
Step 5
Strip the ends of the low voltage wire 
and twist tightly.  Attach these ends to 
the 18 VAC OR SOLAR terminals located 
on the POWER INPUTS terminal block.  
Be certain not to let the exposed wires 
touch each other!
Insert one transformer wire into an 
18 VAC OR SOLAR terminal.  Insert 
the other transformer wire into the 
remaining 18 VAC OR SOLAR terminal.  
The transformer wires can be connected 
to the 18 VAC OR SOLAR terminals 
regardless of color/polarity.
Tighten set screws against exposed end 
of wires.
Step 6
At the transformer, strip 
1
/
2
” of insulation from the ends of the 
low voltage wire.  Attach wires to the transformer terminals. 
Make sure the exposed wires do not touch each other!
DO NOT PLUG THE TRANSFORMER INTO AN OUTLET 
DURING THIS STEP! THE TRANSFORMER MUST ONLY BE 
PLUGGED INTO AN OUTLET DURING STEP 3 (page 15)!
Step 1 
Make sure the control box power switch is OFF. Remove the control box cover and 
slide the battery into position (terminals to the right). 
Connect Battery
~
~
ORG
BLUE
WHT
GRN
BRN
RED
MASTER OPERATOR
BLK
18 VAC
 OR
SOLAR 
ORG
BLUE
WHT
GRN
BRN
RED
BLK
LOCK
PWR
AUX
RLY
LOCK
PWR
AUX
RLY
POWER
INPUT
CONTROL OUTPUTS
MASTER OPERATOR
2ND OPERATOR
2ND OPERATOR
Power Cable
from Master Arm
RED
BLACK
Low Voltage Wire
from AC Transformer
or Solar Panel
ON/OFF Switch
ON/OFF