Impinger I -–1000 Series Service Manual - Domestic 
31 
 
 
Conveyor Drive (Stepper) 
Control 
Perform all checks as in the above evaluation. If 
the time check is okay, refer to the next section. 
Check to see if the conveyor drive (stepper) motor 
is running. If motor is not running, refer to 
"Conveyor will not run" on page 28. 
Magnet 
Check to insure that the magnet (cemented to shaft 
of conveyor drive (stepper) motor) has not been 
damaged, or come loose from motor shaft. 
Replace as needed. 
Hall Effect Sensor 
Check for any physical damage to Hall  Effect 
sensor (mounted on conveyor drive(stepper) 
motor). Check all wiring and connections for 
damage. 
Time Display 
inaccurate, erratic, or 
inoperative(S/N 
Q19078 & Above1000 
Series) (S/N Q14791 & 
Above1200 Series) 
Conveyor Drive (Stepper) 
Control 
Check all connections for tightness or proper 
location and check all wiring for visible damage. 
Replace as needed. If there is still no time display, 
wire in (temporarily) a new conveyor drive control. 
If there is still no time display, reconnect original 
conveyor drive control. Replace Hall Effect Sensor.