Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power to microwave oven and discharge the 
high voltage capacitor before servicing, unless testing requires power. 
16 16027303 
© 2006 Maytag Services
 
 
Illustration Component 
Test 
Procedure 
Results 
 
Ventilation Motor 
JMV8166BA*, AMV6167BD*
 
Discharge Capacitor 
Remove two wires to run capacitor and 
measure resistance across the wires ...........
 
 
Approx. 75 Ω. (Tests all 3 windings.) 
 
Ventilation Motor 
JMV9169BA*
 
Discharge Capacitor 
Remove two wires to run capacitor and 
measure resistance across the wires ...........
 
 
Approx. 25 Ω. (Tests all 3 windings.) 
 
Vent Blower Motor (run) 
Capacitor 
Discharge Capacitor 
 
Remove one wire from capacitor terminals 
and connect ohmmeter. Set on highest 
resistance scale. 
Between Terminals:
 Meter should 
momentarily indicate several ohms, 
then return to infinity (deflection). If 
no deflection occurs, or if continuous 
deflection occurs, replace capacitor. 
Terminal to Case:
 Infinite resistance. 
 
Cavity (Flame Sensor) 
Thermal Cut-Out 
(Thermostat) 
Disconnect all wires from TCO. 
Measure resistance across terminals ..........
Non–resetable. 
Open:
..... 212° F (100° C). 
 
Cavity (Flame Sensor) 
Thermal Cut-Out 
(Thermostat) 
Disconnect all wires from TCO. 
Measure resistance across terminals ...........
Resetable. 
Open:
..... 302° F (150° C). 
Closed:
.. 140° F (60° C). 
 
Cavity (Flame Sensor) 
Thermal Cut-Out 
(Thermostat) 
Disconnect all wires from TCO. 
Measure resistance across terminals ..........
Non–resetable. 
Open:
..... 248° F (120° C). 
 
Magnetron Thermal Cut-Out 
(Thermostat) 
Disconnect all wires from TCO. 
Measure resistance across terminals. ..........
Resetable. 
Open:
..... 302° F (150° C). 
Closed:
.. 140° F (60° C). 
 
Hood Thermal Cut-Out 
(Thermostat) 
Disconnect all wires from TCO. 
Measure resistance across terminals ...........
NOTE:
  This TCO only works in an 
overheat condition.  Otherwise, it will 
measure "open" when testing. 
Resetable. 
Open:
..... 158° F (70° C).  Vent fan  
 engaged. 
Closed:
.. 104° F (40° C). Vent fan  
 disengaged. 
 
Bottom Thermal Cut-Out 
(Thermostat) 
Disconnect all wires from TCO. 
Measure resistance across terminals. ..........
Non–resetable. 
Open:
..... 248° F (120° C). 
 
Sensor 
Remove the red and black wires, connect 
meter to red and black wires and measure 
continuity......................................................
NOTE:  
Do not connect the meter to the 
white and orange wires, as this may 
damage the sensor. 
 
 
30 Ω. 
 
Control Panel Sensor Test 
 
Illustration Component 
Test 
Procedure 
Results 
 
Sensor Test 
Apply power to microwave for 5 minutes. 
Press AUTO DEFROST and REHEAT 
pads simultaneously and monitor display 
for V-Out value .............................................
NOTE:
  Press AUTO DEFROST and 
POPCORN
 pads for model AMV6167BD*
 
 
 
Less than 6 .......... Sensor failure. 
15 to 185.............. Normal. 
More than 213...... Sensor failure. 
1
2
3
 
Sensor Test 
AMV5164B**, 
MMV5165BA*
 
Apply power to microwave for 5 minutes. 
Press AUTO DEFROST and REHEAT 
pads simultaneously and monitor display 
for V-Out value .............................................
 
 
 
Less than 10 .......... Sensor failure. 
10 to 150................ Normal. 
More than 150........ Sensor failure.