LISTING AND CODE APPROVALS 
 
     
THIS VENTED GAS FIREPLACE HEATER HAS BEEN TESTED FOR COMPLIANCE WITH THE ANSI 
STANDARD Z21.88-2002 AND THE CANADIAN CSA 2.33-M02 STANDARDS. THIS UNIT IS LISTED 
WITH INTERTEK TESTING SERVICES (WARNOCK HERSEY, INC.) OF MIDDLETON, WISCONSIN. ALL 
COMPONENTS ARE AGA, CGA, UL OR CSA APPROVED. 
 
     THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY; IF NOT, 
FOLLOW ANSI Z223.1 (NFPA 54), CURRENT EDITION IN THE U.S. OR CAN1-B149, CURRENT EDITION 
INSTALLATION CODE IN CANADA. 
     
      NOTE: SEE LABEL ON THE VALVE FOR GAS PRESSURE TESTING LOCATION. 
 
Performance Summary Table 
 
Characteristic   
 
LP Gas  
 
 
Natural Gas 
 
Fuel 
requirement  LP 
Gas 
   Natural 
Gas 
Input rating (0-610m) 
 
33,200 
BTU/HR 
  32,000 
BTU/HR 
Minimum input (0-610m) 
18,600 BTU/HR  
 
22,500 BTU/HR 
Input rating (610 – 1370m) 
30,200 
BTU/HR 
  29,300 
BTU/HR 
Orifice 
size 
(0-610m) 
 #51 
DMS 
  #33 
DMS 
Max. inlet pressure 
 
13.5” W.C. (3.36 kPa)   
10.5” W.C. (2.61 kPa) 
Min. inlet pressure 
 
11.0” W.C. (2.74 kPa)   
4.5” W.C. (1.12 kPa) 
Max. manifold pressure   
10.0” W.C. (2.49 kPa)   
3.5” W.C. (0.87 kPa) 
Min. manifold pressure   
3.7” W.C. (0.92 kPa) 
 
0.9” W.C. (0.22 kPa) 
Max. 
efficiency, 
with 
fan 
 81.7% 
   77.9% 
Max. output (0-610m) 
 
27,300 
BTU/HR 
  25,400 
BTU/HR 
Gas consumption (std. cond.) 
13.3 Cu. Ft/hr or 0.4 gal/hr. 
32 Cu. Ft/hr 
Fuel supply line  
 
½ inch (13 mm)  
 
½ inch (13mm) 
Flue exit 
 
 
4” Diameter (Top or Rear) 
4” Diameter (Top or Rear) 
Chimney spec.   
 
Type B-1 (4” Dia.) 
 
Type B-1 (4” Dia.) 
Ignition   
 
 
Piezo electric & pilot 
 
Piezo electric & pilot 
Actual 
weight 
  161 
lbs. 
   161 
lbs. 
Shipping 
weight 
  185 
lbs. 
   185 
lbs. 
 
 
SECTION I: FLUE SYSTEM FOR VENTED GAS FIREPLACE HEATER 
 
A.  Installation of a New System (See Installation Drawings at the end of this Manual) 
 
     This vented gas fireplace heater must be connected to four-inch (4”) diameter Type B-1 gas 
pipe. This product is manufactured and certified to NFPA 54 and NFPA 211 “current edition” 
standards. The minimum clearance of this pipe to combustible materials is one inch (1”).  Never 
use aluminum or galvanized steel pipe with this unit. 
     Single wall pipe may be used between the stove and ceiling or stove and wall; a minimum of 
six inches (6”) clearance to combustible materials is required for this type of pipe. It is imperative 
that the single wall pipe be terminated at the ceiling or wall, by connecting to a double wall B-1 
Vent Pipe. Single wall pipe should never pass through a combustible wall or ceiling. Follow the 
pipe manufacturer’s instructions for venting through a combustible area. 
     Installation requirements for single wall pipe or Type B-1 Vent Pipe are specified in the ANSI 
Z223.1 or CAN1-B149 Standard “current edition.” These standards will also indicate proper 
clearances to combustibles. Your stove dealer or qualified service person will be familiar with 
these standards and can properly install the chimney system. 
     Connection of the pipe to the stove is accomplished by placing the pipe over the collar on the 
top or rear of the unit; then secure the connection with a screw through the pipe.