Cleveland Range CSTK-610 Manuel D’Utilisation
Cleveland
™
Project ________________________________
Item __________________________________
Quantity _______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
COMBI OVEN-STEAMER
Stacking Kits for Gas Table Type Models
(OGB 6.10 on OGB 6.10 or OGS 6.10 on OGS 6.10)
Stacking Kits for Gas Table Type Models
(OGB 6.10 on OGB 6.10 or OGS 6.10 on OGS 6.10)
SECT.
IIB
PAGE
5A
0707
by
by
Cleveland
Cleveland
™
Model #
Description
CSTK-610
for mounting two 6.10 models
CSTK-610CA
for mounting two 6.10 models (with casters)
UNIT A
UNIT B
6.00
"
NOTE: Overall height of unit does not change for units with casters.
7
RC
CS
W1
W2
D
G
4.38"
NOTE: Overall height of unit does not change for units with casters.
RC
CS
W1
W2
D
G
RC
CS
W1
W2
D
G
4.38"
38.08"
39.21"
LEFT SIDE VIEW
6.10
on 6.10
GAS
on 6.10
GAS
6
UNIT A
UNIT B
3
36.70"
1.58"
2
8
.4
3
5.00"
1.82"
6
7
.8
5
"
2
8
.4
3
6.00"
7
8
.0
0
”
(M
IN
.H
O
O
D
R
E
Q
U
IR
E
M
E
N
T
)
2.52"
7
UTILITIES
(Utility connection shown below are listed per unit)
Required Clearances:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located
next to the unit.
• Allow for sufficient clearance on left side for service access (contact the
factory service department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
120 volt, 60 Hz, single phase, UNIT A - 11.7 amps
Do not connect to a G.F.I. outlet.
UNIT B - 11.7 amps
Gas Connection:
3/4" NPT
Gas Type:
Natural Gas (Propane optional)
Gas Flow Pressure:
Natural Gas - Min. 5.5" WC / Max. 14" WC
Propane Gas - Min. 11" WC / Max. 14" WC
BOILER MODELS
UNIT A - OGB-6.10
UNIT B - OGB-6.10
Total Connected Load:
45.400 BTU
45.400 BTU
Steam Generator:
45.400 BTU
45.400 BTU
Hot Air:
45.400 BTU
45.400 BTU
BOILERLESS MODELS
UNIT A - OGS-6.10
UNIT B - OGS-6.10
Total Connected Load:
45.400 BTU
45.400 BTU
Hot Air:
45.400 BTU
45.400 BTU
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2
Water Connections:
Cold Water (drinking water quality)
Flow Pressure:
30 - 60 PSI
Water Inlets:
3/4" GHT-F (Female Garden Hose Connection)
Treated Water for Steam Generator
Untreated Water for Condenser
Drain Connection:
2" Tube
Venting:
Exhaust Hood required
*Connection for Cleaning Solution
*Connection for Rinse Cycle
*Available as an option
Note: For additional connection details, see spec sheet for each
individual combi model to be stacked.
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
RC
S
CS
AV
G
E1
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
RC
S
CS
AV
G