Fujitsu TX200 S3 Manuel D’Utilisation

Page de 10
If you would like to order internal HDDs and internal backup devices, please order optional cards/cables according to the following table.
Standard Drive Cage
(6bays)
Standard Drive Cage
(6bays)
(''1) USB Backup Devices: PG-DT504
(''2) SCSI Wide Backup Devices: PG-LT302/PG-LT201/PGBLT201C1/PG-LT102
(''3) If you order internal backup devices by CTO, SCSI cable is attached with backup devices.
HDD SAS 15k 73GB hot plug 3.5inch
SAS Controller
PG-HDB75A
( installed as standard )
PGBHDB75A (for CTO)
*. In case that SAS Controller installed
   as standard is used for RAID configuration,
HDD SAS 15k 147GB hot plug 3.5inch
   only 2 HDDs of same capacity and same
Internal HDD Unit Bay
PG-HDB45A
   rpm can be connected.
Conversion kit
PGBHDB45A (for CTO)
*. RAID1 configuration can be set.
PG-BC103
*. Hot spare disk cannot be set.
HDD SAS 15k 300GB hot plug 3.5inch
PG-HDB35A
PGBHDB35A (for CTO)
*. When Internal HDD Unit Bay Conversion kit
SAS RAID Ctrl
   (PG-BC103) is applied, up to 8 Internal HDDs
(without BBU)
   can be mounted but internal backup devices
PG-140F
   cannot be mounted on 5inch Bays.
PGB140F (for CTO)
*. RAID 0/1/5/1+0 configuration can be set.
   To set RAID configuration, two or more HDDs
   which are same capacity and same rpm
   should be connected to SAS Controller
   installed as standard.
SAS RAID Ctrl
(with BBU)
PG-140G
PGB140G (for CTO)
*. RAID 0/1/5/1+0 configuration can be set.
   To set RAID configuration, two or more HDDs
   which are same capacity and same rpm
   should be connected to SAS Controller
   installed as standard.
SAS RAID Ctrl (PG-140F/PG-140G)
( SAS Controller (standard) )
When Internal HDD Unit Bay
Conversion kit (PG-BC103) is
applied. (+2bays)
When Internal HDD Unit Bay
Conversion kit (PG-BC103) is
applied. (+2bays)
 
Drive Cage
-
(not connect)
RAID
SAS Controller (standard)
*. In case that SAS Controller installed as standard
   is used for RAID configuration, only 2 HDDs of same
   capacity and same rpm can be connected.
Type of HDD connection
Interface
SAS Controller (standard)
*. Only SAS Configuration is supported.
Onboard USB
(internal port)
SAS RAID Ctrl (PG-140F/PG-140G)
( SAS Controller (standard) )
SAS /
RAID
Internal Backup Devices PRIMERGY TX200 S3
SCSI Card (PG-1281/PGB1281)
SCSI Cable (PG-CBLS025)  (''3)
Onboard USB
(internal port)
Connection
SCSI Card (PG-1281/PGB1281)
SCSI Cable (PG-CBLS025)  (''3)
-
(not connect)
USB (''1) Connection
SCSI Wide (''2) Connection
-
(not connect)
-
(not connect)
Connecting Internal HDD and Internal Backup Devices
SAS / RAID Configuration
Internal HDD
PCI Bus
RAID Configuration
PCI Bus
PRIMERGY  TX200 S3