Thermocouple
Pilot Burner
Figure 27 - Correct Pilot Flame Pattern 
(Propane/LP Shown)
Figure 28 - Incorrect Pilot Flame Pattern 
(Propane/LP Shown)
Thermocouple
Pilot Burner
INSPECTING bURNER
Check pilot flame pattern and burner flame pat-
tern often.
PILOT FLAME PATTERN
Figure 27 shows a correct pilot flame pattern. 
Figure 28 shows an incorrect pilot flame pattern. 
The incorrect pilot flame is not properly heating the 
thermocouple. This will cause the thermocouple to 
cool. When the thermocouple cools, the fireplace 
will shut down.
If pilot flame pattern is incorrect, as shown in 
Figure 28
•  turn fireplace off (see To Turn Off Gas to Ap-
pliance, page 19)
•  see Troubleshooting, page 22
Note:
 The pilot flame on natural gas units will 
have a slight curve, but flame should be blue and 
have no yellow or orange color.
Figure 29 - Correct Burner Flame Pattern
Figure 30 - Incorrect Burner Flame 
Pattern
bURNER FLAME PATTERN
Figure 29 shows a correct burner flame pattern. 
Figure 30 shows an incorrect burner flame pattern. 
The incorrect burner flame pattern shows sporadic, 
irregular flame tipping. The flame should not be 
dark or have an orange/reddish tinge.
Note:
 When using the fireplace the first time, the 
flame will be orange for approximately one hour 
until the log cures. 
If burner flame pattern is incorrect, as shown in 
Figure 30
•  turn fireplace off (see To Turn Off Gas to Ap-
pliance, page 19)
•  see Troubleshooting, page 22
CLEANING AND 
MAINTENANCE
 WARNING: Turn off fireplace 
and let cool before cleaning.
  CAUTION:  You  must  keep 
control  areas,  burner  and  cir-
culating  air  passageways  of 
fireplace  clean.  Inspect  these 
areas  of  fireplace  before  each 
use.  Have  fireplace  inspected 
yearly  by  a  qualified  service 
person.  Fireplace  may  need 
more frequent cleaning due to 
excessive  lint  from  carpeting, 
bedding material, pet hair, etc.
  WARNING:  Failure  to  keep 
the  primary  air  opening(s)  of 
the burner(s) clean may result in 
sooting and property damage.
BURNER INjECTOR HOLDER AND 
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper amount 
of air to mix with the gas. This provides a clean 
burning flame. Keep these holes clear of dust, dirt, 
lint and pet hair. Clean these air inlet holes prior to 
each heating season. Blocked air holes will create 
soot. We recommend that you clean the unit every 
three months during operation and have heater 
inspected yearly by a qualified service person.