4.  If you smell gas
•  shut off gas supply
•  do not try to light any appliance
•  do not touch any electrical switch; do not 
use any phone in your building
•  immediately call your gas supplier from 
a  neighborʼs  phone.  Follow  the  gas 
supplierʼs instructions
•  if you cannot reach your gas supplier, call 
the fire department
5.  This heater shall not be installed in a bedroom 
or bathroom unless installed as a vented appli-
ance (Variable Manually-Controlled Models 
Only) (see Installing Damper Clamp Acces-
sory for Vented Operation, page 11).
6.  Before  installing  in  a  solid  fuel  burning 
fireplace, the chimney flue and firebox must 
be cleaned of soot, creosote, ashes and loose 
paint by a qualified chimney cleaner. Creosote 
will ignite if highly heated. A dirty chimney 
flue  may  create  and  distribute  soot  within 
the house. Inspect chimney flue for damage. 
If damaged,  repair  flue and firebox before 
operating heater.
7.  Do not burn solid-fuel in a masonry or UL127 
factory-built fireplace in which a vent-free 
room heater is installed.
8.  If fireplace has glass doors, never operate this 
heater with glass doors closed. If you operate 
heater with doors closed, heat buildup inside fire-
place will cause glass to burst. Make sure there are 
no obstructions across openings of fireplace.
9.  This log heater is designed to be smokeless. If 
logs ever appear to smoke, turn off heater and 
call a qualified service person. Note: During 
initial operation, slight smoking could occur 
due to log curing and heater burning manufac-
turing residues. 
10.  To prevent the creation of soot, follow the instruc-
tions in Cleaning and Maintenance, page 23.
11.  Before  using  furniture  polish,  wax,  carpet 
cleaner or similar products, turn heater off. If 
heated, the vapors from these products may 
create a white powder residue within burner 
box or on adjacent walls or furniture.
12.  This heater needs fresh, outside air ventilation 
to run properly. This heater has an Oxygen De-
pletion Sensing (ODS) safety shutoff system. 
The ODS shuts down the heater if not enough 
fresh air is available. See Air for Combustion 
and Ventilation, page 5. If heater keeps shutting 
off, see Troubleshooting, page 25.
13.  Do not run heater
•  where  flammable  liquids  or  vapors  are 
used or stored
•  under dusty conditions
14.  Do not use this heater to cook food or burn 
paper or other objects.
15.  Do not use heater if any part has been exposed 
to or under water. Immediately call a qualified 
service technician to inspect the room heater 
and to replace any part of the control system and 
any gas control which has been under water. 
16.  Do not operate heater if any log is broken. Do 
not operate heater if a log is chipped (dime-
sized or larger). 
17.  Turn heater off and let cool before servicing. 
Only a qualified service person should service 
and repair heater.
18.  Operating heater above elevations of 4,500 
feet could cause pilot outage.
19.  Provide  adequate  clearances  around  air 
openings.
LOCAL CODES
Install and use heater with care. Follow all local 
codes. In the absence of local codes, use the lat-
est edition of The National Fuel Gas Code, ANSI 
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY  10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA  02269
Note:
 Where listed vented decorative logs are 
required, thermostat operation is not permitted.
SAFETY INFORMATION
Continued
State  of  Massachusetts:  The  installa-
tion must be made by a licensed plumber 
or  gas  fitter  in  the  Commonwealth  of 
Massachusetts.
Sellers  of  unvented  propane  or  natural 
gas-fired supplemental room heaters shall 
provide to each purchaser a copy of 527 
CMR 30 upon sale of the unit.
Vent-free  gas  products  are  prohibited  for 
bedroom  and  bathroom  installation  in  the 
Commonwealth of Massachusetts.