Amana AK2H30 Manuel D’Utilisation

Page de 47
Troubleshooting Procedures
RS2420002   Rev. 5
15
Multi
Position Switch
Continuity Test
1.  Remove all wires connected to the control.
2.  Turn control to OFF. Check for continuity between
each contact (1
1a, 2
2a, 3
3a, ect.) except
contacts 7
7a. If continuity is found between any
contacts, the switch has failed and must be replaced.
3.  There is a diode across contacts 7
7a. With the
control turned to OFF, check continuity across this
contact. Ohmmeter must be set at 10 K
Ω
 setting to
check diode measurement. There should be no
continuity one direction and continuity the other
direction. If this indication is not obtained, switch has
failed and must be replaced.
4.  Use the matrix above to determine if the switch is
closing the proper contacts at a particular setting. If
switch does not match the matrix the switch has
failed and must be replaced.
5.  The switch thermostat is between terminals 5 and 1a,
Replace the switch if an open exists between these
terminals.
NOTE: The halogen element being controlled by the
multi
position switch will vary in intensity and not
cycle on and off unless the limiter switch opens.
L1
N
"ON"LT
10a
11a
6a
5a
6
5
1b
2b
2a
1a
10
4a
4
3a
1
2
1a
2a
7
7a
9
8
9a
8a
L2
Lamp Inner Outer
4
3
2
1
Switch Schematic
(Switch Off, Element at Room Temperature)
Switch
Power
Lamp
Brightness
Heater
Power %
Power Output (Watts)
1200        1500         1800
10
Full
100
1200
1500
1800
9
High
76
920
1145
1370
8
High
56
670
835
1000
7
Medium
41
495
620
740
6
Medium
30
360
450
540
5
Low
23
275
345
410
4
Low
16
190
240
290
3
Invisible
11
135
170
200
2
Invisible
8
100
125
150
1
Invisible
6
65
85
100
Haloring 10
Position Switch
Operating Characteristics