BURNER FLAME PATTERN
Burner flames will be steady; not lifting or floating. Flame patterns 
will be different from unit to unit and will vary depending on instal-
lation type and weather conditions.
If the vent configuration is installed incorrectly, the flames will lift 
or "ghost". This can be dangerous. Inspect the flames after instal-
lation to ensure proper installation and performance. 
Figure 51 shows a typical flame pattern. 
If burner flame pattern differs from that described:
•  turn fireplace off (see To Turn Off Gas to Appliance, page 24) 
•  see Troubleshooting, page 27
Figure 51 - Typical Flame Pattern
Pilot Burner
Ignitor/Sensor
INSPECTING BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper flame. Altera-
tions may have occurred during shipping and handling. The pilot 
is located on the left hand side of the burner.
The  flame  must  envelope  1/4"  of  top  of  the  ignitor/sensor  and 
grounding stem. 
If your pilot assembly does not meet these requirements:
•  Turn the adjustment screw marked PILOT clockwise to decrease 
or counterclockwise to increase the flame to proper size (see 
Figure 48, page 24). Do not remove the adjustment screw.
•  see Troubleshooting, page 27
Figure 50 - Correct Pilot Flame Pattern
Sensing Rod
INSPECTING BURNERS
Pilot Assembly
Burner Flame Pattern
CLEANING AND MAINTENANCE
Glass Door
CLEANING AND 
MAINTENANCE
 WARNING: Turn off fireplace and let cool before 
cleaning.
 CAUTION: You must keep control areas, burners 
and circulating air passageways of fireplace clean. 
Inspect  these  areas  of  fireplace  before  each  use. 
Have fireplace inspected yearly by a qualified service 
person. Fireplace may need more frequent cleaning 
due to excessive lint from carpeting, bedding mate-
rial, pet hair, etc.
GLASS DOOR
  WARNING:  Handle  glass  door  panel  with  care. 
Do  not  strike,  slam  or  otherwise  abuse  glass.  Do 
not operate fireplace with the glass door unlatched, 
removed, cracked or broken.
 WARNING: Do not use abrasive cleaners as this 
may damage glass. Use a nonabrasive household glass 
cleaner to clean glass. Do not clean glass when hot.
Glass must be cleaned periodically. During start-up it is normal for 
condensation to form on the inside of the glass causing lint, dust and 
other airborne particles to cling to the glass surface. During initial 
start-up a slight film may form on the glass due to paint curing. 
The glass should be cleaned several times with a non-ammonia, 
nonabrasive household cleaner and warm water after the first two 
weeks of operation. Thereafter, clean the glass two or three times 
during each heating season, depending on the usage and circum-
stances present. Refer to Removing/Replacing Glass Door on page 
20 of this manual when removing glass door for cleaning.
  WARNING:  Only  parts  supplied  by  the  manu-
facturer should be used when replacing broken or 
damaged glass door panel (see Replacement Parts
page 29). This glass door panel is a complete unit. 
No substitute materials may be used.
 CAUTION: Wear gloves and safety glasses while han-
dling or removing broken glass. Do not remove if glass 
is hot. Keep children and pets away from glass.
If glass has been broken, carefully remove glass door (see Remov-
ing/Replacing Glass Door
, page 20). Vacuum all glass pieces with 
a shop vac.
 CAUTION: Do not vacuum if pieces are hot.