Enterasys csx400 Mode D'Emploi
Flash Download Screen
Local Management User’s Guide
1-27
RUNTIME Download
If you select RUNTIME Download, perform the following steps:
1.
Use the arrow keys to highlight the Reboot After Download field.
2.
Press the SPACE bar or BACKSPACE to select one of the following:
•
YES, if you want the HSIM or CyberSWITCH to reboot and use the new firmware image
immediately.
immediately.
•
NO, if you want the HSIM or CyberSWITCH to continue using the existing firmware
image without interrupting network operation. The HSIM or CyberSWITCH stores the new
firmware image in flash memory. When you reset the HSIM or CyberSWITCH, it boots
from flash memory using the new image.
image without interrupting network operation. The HSIM or CyberSWITCH stores the new
firmware image in flash memory. When you reset the HSIM or CyberSWITCH, it boots
from flash memory using the new image.
3.
Use the arrow keys to highlight the Download Server IP field.
4.
Type the IP address of the download server and press ENTER.
5.
Use the arrow keys to highlight the Download File Name field.
6.
Type the complete path and filename of the new image file to be downloaded. You must include
all directories and subdirectories involved in accessing the file. Type the new entry over the
previous entry. For example: c:\images\cyberswitch\11011.hex
all directories and subdirectories involved in accessing the file. Type the new entry over the
previous entry. For example: c:\images\cyberswitch\11011.hex
7.
Press ENTER.
8.
Use the arrow keys to highlight the EXECUTE command located at the bottom of the Flash
Download screen.
Download screen.
9.
Press ENTER to begin the download. The HSIM or CyberSWITCH attempts to download the
file using the IP address, filename, and path provided. This file is assigned to the Flash memory
of the HSIM or CyberSWITCH.
file using the IP address, filename, and path provided. This file is assigned to the Flash memory
of the HSIM or CyberSWITCH.