PRE-INSTALLATION
2
Floor under product 
MUST be at or above the same level as the surrounding FINISHED floor, for ease of installa-
tion and removal.
Electrical: Provide 115 Volt, 60 Cycle, Single Phase, 15 Amp, AC Receptacle.  It is recommended that a separate 
circuit, serving only this appliance, be provided.  *Two (2) units side-by-side require separate circuits, except the 
60SS and 72SS (see Instruction Sheet 34361-000).  Electrical opening should be placed 78 1/2 inches minimum 
from the floor.
Plumbing: Ice maker water supply line (1/4 inch OD copper tubing) to come up the rear of cut-out opening ap-
proximately 78 inches off the floor depending on height adjustment.  Tubing should then pass around the right side 
of the module and around the front to the solenoid valve (see Installation Instructions provided with the unit).
Cut-Out Detail for 1 Unit
Cut-Out Width = “A”
*Cut-Out Detail for 2 Units
Placed Side by Side
Cut-Out Width = “A” + “A” + 1/2”
Model
Cut-Out 
Width 
(inches)
18AR
17 1/2
18AF
17 1/2
18TF
17 1/2
18WC
17 1/2
24AR
23 1/2
24AF
23 1/2
24TF
23 1/2
24WC
23 1/2
24BC
23 1/2
242Z
23 1/2
30AR
29 1/2
30AF
29 1/2
30TF
29 1/2
36AR
35 1/2
36AF
35 1/2
36TF
35 1/2
36SS
35 1/2
363D
35 1/2
42SS
41 1/2
48SS
47 1/2
54SS
53 1/2
60SS
59 1/2
66SS
65 1/2
72SS
71 1/2
NOTE: Allow for three (3) inch high removable filler panel for easy removal of power module.
Receptacle must be placed in 
this location for 18” models.
22”
22”
Ice Maker 
Tubing
20”
Min. (typ)
*See note below.
A
A
A
83 3/4” 
to 
84 1/2”
24”
24”
78”
approx.
78 1/2”
Min. 
(typ)
1/2”
83 3/4” 
to 
84 1/2”