Dynamic Form Commands
 71
Dynamic Form: Repeat
Purpose
Repeats (duplicates) an entire form within a boilerplate dynamic 
form.
Format
(cc) R 
formdata (cc)Z(cc)-
(cc)
Represents the Special Function Control Code 
(SFCC). Enter the specific SFCC for your VGL 
configuration.
R
Specifies the Dynamic Form: Repeat command. 
Enter R to repeat the boilerplate form.
formdata
Represents the dynamic form data. Any text, 
graphics command sequences, or dynamic form 
field length, are entered as part of the data. 
This is 
not the dynamic data for the variable fields; 
this data represents all information required for the 
boilerplate form to be repeated. The number of 
copies of the form is specified as part of the 
dynamic data sequence after the dynamic form is 
processed.
(cc)Z(cc)-
Terminates the repeat sequence. Enter the SFCC 
for your VGL configuration immediately followed by 
Z, another SFCC, and - or another valid graphics 
command mnemonic to terminate the Dynamic 
Form Copy Fields sequence.
Comments
The Dynamic Form: Repeat command is supplied as the first 
input of the data parameter within the Dynamic Form command. 
Do not use this command with the Dynamic Form: Copy Fields 
command (page 69).
The LF and FF commands (as previously described on page 66) 
have an additional meaning when used with Dynamic Form: 
Repeat commands.
When the data is supplied, the first parameter becomes a four-
digit repeat number field. For example, 0003 before the first 
dynamic data byte specifies three repeated forms with the data. 
The repeat number field must be supplied with each set of data 
when the Dynamic Form: Repeat command is used. If only one 
copy of the form is required, enter 0001 as the repeat number.