Printronix P7000 Manuel D’Utilisation

Page de 338
Terminating Resistor Configurations
243
V6 Controller Board
For parallel interface configurations, the printer is equipped with 470 Ohm and 
and 1K Ohm terminating reistors on the controller board. These are suitable 
for most applications. See Figure 25.
If the standard terminating resistor pack is not compatible with the particular 
interface driver requirements of the host computer, other RP1 and RP2 values 
may be required. 220 Ohm and 330 Ohm alternate terminating resistors are 
provided with the printer. If you install the 220 Ohm resistor, you must also 
install the 330 Ohm resistor. Possible terminating resistor combinations are 
shown below.
Figure 25. Terminating Resistors, V6 Controller Board
Removal And Installation
The procedure for removing and installing terminating resistors is provided in 
your 
Maintenance Manual.
CAUTION
This is an involved maintenance procedure. To avoid damage to the 
equipment, only a trained technician should perform this procedure.
Configuration
RP1
RP2
Factory Default
470 Ohm
1K Ohm
Alternate
220 Ohm
330 Ohm
7h
te
rm
rs
Default: 470/1K Ohm
Alt: 220/330 Ohm
RP1 and RP2