Quantum SuperLoader 3 Note De Mise

Page de 8
Release Notes
Document 5502229 Rev B
July 2008
Resolved Issues
3
Resolved Issues   
0
This release of SuperLoader 3 V61 firmware resolved the following issues
19003
Invalid media error with the HP LTO-3 drive
19018
HP LTO-3 load failure
.
Known Issues
0
This release of SuperLoader 3 V61 firmware has the following known issues:
System
0
PCR17902 — OCP Enable/Disable barcode doesn't give immediate power cycle 
message
0
When changing the barcode scanner configuration on the OCP, the user is not 
immediately notified that a power cycle is required. The user must hit the ESC key to get 
to the top level before the message is displayed. However, until the user power cycles, 
active operations from the OCP are not allowed.
Code Update
0
PCR4564 — Firmware update fails with Firefox on Windows Vista 
0
When performing a firmware update of the autoloader system code over the RMU, do not 
use the combination of the Firefox browser on the Windows Vista® operating system. The 
update can fail, but will not adversely affect the operation of the system. This has been 
observed using V43 and later versions. Tech Bulletin 6-01828-07 “SuperLoader 3 
Firmware Update Fails with Firefox on Windows Vista” has been issued. The IE7 browser 
on Vista works without problem, and Firefox on Win 2003 works without problem. Other 
combinations of browsers and operating systems may be fine.
PCR17898 — OCP gives no indication that drive FW is being updated
0
While updating drive code over SCSI, the OCP shows “Updating Drive” if the OCP is at 
the top menu. If the OCP is at a submenu item, the message does not appear. Hitting the 
ESC key to return to the top level shows the “Updating Drive” message. The message 
shows periodically. While drive code is being updated, moves involving the drive are not 
allowed.
PCR 
Number
Description