Hafler p4000 Guide De Spécification

Page de 2
S
PECIFICATIONS
P4000
Power Rating ..................................................................... 200 Watts/channel @ 8
Ω
275 Watts/channel @ 4
Ω
550 Watts bridged/mono @ 8
Ω
Total Harmonic Distortion (THD) ................................................ <0.2% (20Hz-20kHz)
Signal-to-Noise .......................................................................... 100dB “A” Weighted
Full Power Bandwidth ..................................................... 0.2Hz to 200kHz (+0/–3dB)
Slew Rate ....................................................................................................... 100V/
µ
s
CMRR (Common Mode Rejection Ratio) .............................................. 75dB at 1kHz
Input Impedance ........................................................... 47k
Ω
 per phase balanced
Gain ................................................................................... –29dB min. / +29dB max.
Input Sensitivity Range .......................... 710mV to 4V (@ 8
Ω
) per phase balanced
592mV to 4V (@ 4
Ω
) per phase balanced
Damping Factor ..................................................................................... 500 (to 1kHz)
150 (to 10kHz)
18 (to 100kHz)
Power Consumption ............................................ 120W / 1.0A @ 120VAC (idle power)
250W / 2.1A @ 120VAC (1/8 power – 8
Ω
)
720W / 6.0A @ 120VAC (max. power – 8
Ω
)
Indicators .................................................. Power, Signal, Clipping, Thermal, Short
Dimensions ......................................................... 19”W x 11”D x 5
1
4
”H (3-rack spaces)
(48.26cm x 27.94cm x 13.34cm)
Net Weight ........................................................................................ 34 lbs. (15.42kg)
A
m
p
l
i
f
i
e
r
P4000
®
A
RCHITECT
S
 
AND
 E
NGINEER
S
 S
PECIFICATIONS
The audio power amplifier shall be solid state design employing 12 lateral
power MOSFET output devices. It shall be constructed on a 16 gauge steel
chassis utilizing convection cooling and be technician friendly using modular
construction.
Each channel shall be rated for a minimum of 200 watts into an 8 ohm load and
275 watts into a 4 ohm load with both channels driven. In bridged mono mode,
the amplifier shall produce at least 550  watts into an 8 ohm load. A switch shall
be provided for stereo or bridged mono operation and all power ratings shall
be measured from 20Hz-20kHz with less than 0.2% THD.
The amplifier’s back panel shall provide Balanced inputs via combination XLR
and 1/4” phone jacks. The back shall also utilize gold-plated 5-way binding
posts for output connectors and a switch to isolate or connect the signal
ground to the chassis ground. The amplifier shall include a 3-wire grounded
AC line cord and UI power transformer operating on 120V/60Hz AC mains. An
optional transformer for 230V 50-60Hz operation shall be available.
The amplifier’s front panel shall provide full range level controls with optional
security covers. The front shall also incorporate a lighted main power switch
and indicators for each amplifier channel. The indicators shall display signal
present when 30mV of signal is detected, signal clipping when distortion rises
above 1%, thermal protection should the heatsink temperature become exces-
sive, and short circuit protection in case a problem on the speaker system
arises.
The amplifier shall fit standard 19” EIA rack mounting requirements utilizing 3-
rack spaces. The dimensions shall be 19” Wide, 11” Deep, 5
1
4
” High, and be
finished in black with a net weight of 34 pounds. It shall be a Hafler P4000.
CH 2
120 V~
60Hz
520W
CH 1 (Mono)
A Division of Rockford Corp.
Tempe, AZ 85281  U.S.A.
Made in the U.S.A.
Audio Ground
Chass. Float
C H   1
 
+
8
Ω
C A U T I O N
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING:  DO NOT REMOVE COVER
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
!
XLR Connections
3
2
1
+
Phone Connections
+
C H   2
 
+
 
+
Mono
125 V T15A
®
4–8
Ω
4–8
Ω
PUSH
PUSH
Attention: Utiliser un fusible de rechange de même type.
CAUTION: For continued protection from risk of fire,
replace only with same type and rating of fuse.
Class 2
Wiring
P 4 0 0 0
UL
®
UL
®
C