Nuvo nv-a4ds-dc Mode D'Emploi

Page de 20
5
1
2
SOURCE  INPUT 
L
R
L
R
1
2
3
4
L
R
ZONE 4
FIXED
VAR
LINE OUT 
IR OUT
1
3
2
4
SYSTEM
LINK
RS232
STATUS
ON=+12V
MUTE
=0V
SPEAKER AND DATA SIGNALS
ALL PORT CONNECTION
Simplese
CONFORMS TO
UL STD.6500
CERTIFIED TO
CAN/CSA STD.E60065
3033118
C
US
RT
E E
T
K
N
I
CM
NuVo Technologies Cincinnati Ohio USA
D
RT
E E
T
K
N
I
FOUR-SOURCE FOUR-ZONE
100~240V       50~60Hz  85W
USE FOR SAT
OR CABLE
NORMAL
USE
56KHz
38KHz
1
2
1
2 34
5
6
7 8
9
Front Panel Features
1.  Stand-by LED 
This LED (light emitting diode) indicates, when lit, that the Simplese amplifier is plugged into 
an AC power source.
2.  Zone LED 
 
Each of these LEDs indicates, when lit, that its zone keypads are turned on. 
Back Panel Features
1.  Source Inputs
Each of these stereo RCA inputs receives an audio signal from up to four independent audio 
sources.
2.  Zone 4 Lineouts
These fixed and variable lineouts are used for attaching additional amplification to the zone 4 
audio outputs.
3.  IR OUT
These outputs are designed to be used with the included IR (Infrared) emitters to transfer IR 
function commands from the zone keypads to the appropriate audio source equipment; see IR 
Outputs pg. 9.
4.  MUTE
This 3.5mm mono connection is designed to be used in conjunction with the NV-MI1 mute 
interface; see Mute Input and the NV-MI1, pg. 13.
5.  STATUS
This 3.5mm mono connection provides a constant +5 volt output when a zone is turned on. This 
can be used to trigger external equipment.
6. RS232
This is used for factory purposes only and has no system function relevance. 
7. LINK
This 3.5mm stereo output is used to expand the Simplese System from four to eight zones; see 
Using the Link Jack to Create Eight Zones, pg. 13.
8.  Allport Connection
This 25-pin terminal is used in conjunction with the Allport cable to integrate the zone keypads 
and speakers into the system; see Allport Termination and Installation, pg. 8.
9.  AC 
This is used with the included AC power cable to provide electrical power to the system when 
attached to an active AC power outlet.