Nuvo NV-I8GXS Manuel De Montage

Page de 41
Re-Ordering Macro Codes
After a code is added to a macro, highlighting a code and 
clicking on the Ý
 or ß
  button will reorder the codes. 
Macros (updated)
After editing a macro, the macro list is updated to show the 
number of IR codes and the display name.
Note that the Macro tab has an additional button at the 
bottom that says “Update Macros From Library.” If codes 
were edited in any way in an IR library after a source has 
been defined in the Source tab, this button will 
automatically pull those changes into the Macro Definition 
window.
4.1.3 Control Macros 
An additional option within the Macro tab is the ability to 
establish multiple control macros. These macros are 
intended for instant access to control functions and are an 
optional feature. If a control macro is created, an additional 
source menu item is also created titled “Control” preceded 
by the three character “short name” assigned in the Source 
tab.
Creating a control macro is the same process outlined in 
4.1.1
 Creating a Preset Macro String on page 17.
18
5. Zones (Fig. 24)
Up to 20 zones can be defined with the Grand Concerto. Each 
zone can be defined with unique properties. 
You will notice that the zone tab contains 20 entries for zone 
Control Pads. The system can accommodate a total of 
20Control Pads by using the slave function in the “Edit Zone 
Properties” window. A slave Control Pad is homerun to the EZ 
Port, but automatically shares the same functions and works 
in tandem with the main zone Control Pad. Up to three slave 
Control Pads can operate on a single zone.
Fig. 24
5.1 Edit Zone Properties (Fig. 25)
Double-clicking on a zone number opens the “Edit Zone 
Properties” window. Specific properties defining that zone 
are set here. 
Max Volume: This allows the volume in a zone to be limited. 
This can be done either to avoid damage to low-power 
speakers or simply to prevent a certain room from being 
turned up too high (e.g., a teenager's bedroom). 
Party Volume:  This controls the reset volume level for each 
zone when the All On/Party Mode is initiated from any of the 
Control Pads. The range is –78dB to –30dB.
Page Volume:  If you are using the paging feature of the 
Grand Concerto System, you can also set the specific volume 
level of the page zone by zone, by using this volume control. 
The range is –78dB to –30dB, with a default at –40dB.
Balance:  The level of output to the left and right speakers is 
adjusted here. The default is center, but depending on the 
location of the speakers and the optimal listening area of 
the room, it may be advantageous to adjust the balance to 
either the left or the right.