Enterasys csx150 Mode D'Emploi

Page de 620
USER’S GUIDE
180      CyberSWITCH
7.
Enter a list of bearers (a channel map).The range of channels is from 1 to 2. Separate bearer 
channels by commas, and/or list a range by using a dash (-).
LAPB C
ONFIGURATION
 I
NFORMATION
Note:
You will not be prompted for this information if you are using X.25 over a D-Channel. The 
system will “know” what type of X.25 access you are using by the line you selected for the 
access. If you select a line that has its data link configured to support X.25 communications, 
then you are selecting a line that will do X.25 over a D-Channel.
1.
Enter the LAPB sequence number range to use, regular, or extended. Extended sequence 
numbering allows for frames to be assigned sequence numbers from 0-127 (modulo 128), as 
opposed to 0-7 (modulo 8).
2.
Enter the duration of Timer T1, which is the maximum time to wait for responses to pending 
commands. 
3.
Enter the duration of Timer T3, which is used to signal that an excessively long idle time is 
occurring on the link. LAPB requires that Timer T3 be greater than Timer T1.
4.
Enter the maximum number of frame re-transmissions that can be performed (this is 
commonly known as “N2”).
5.
Enter the maximum number of frames that the transmitting station may have outstanding at 
any given time (this is commonly known as “K”). The range for this parameter will be 1-7 if the 
Modulo 8 sequence numbers are being used for LAPB, or 1-127 if Modulo 128 sequence 
numbers are being used.
X.25 C
ONFIGURATION
 I
NFORMATION
1.
Configure the X.25 Logical Channel Assignments. This requires entering the maximum 
number of PVCs and SVCs to be supported. For X.25 over B-channel, a total of 48 virtual 
circuits are supported; over D-channel 8 virtual circuits are supported. Therefore, the total 
number of PVCs and SVCs combined cannot exceed the maximum number of VCs.
a.
Enter the maximum number of PVCs to support.
b.
Enter the maximum number of SVCs to support.
2.
Configure the X.25 Timers.
a.
Enter the duration of Timer T20.
This timer designates the time limit in which a restart confirmation must be returned by the 
DCE (the PPSN) after a restart request has been issued by the DTE (the CyberSWITCH).
b.
Enter the duration of Timer T21.
This timer designates the time limit in which a call connected response must be returned 
by the DCE (the PPSN) after a call request has been issued by the DTE (the CyberSWITCH).
c.
Enter the duration of Timer T22.
This timer designates the time limit in which a reset confirmation must be returned by the 
DCE (the PPSN) after a reset request has been issued by the DTE (the CyberSWITCH).
d. Enter the duration of Timer T23.
This timer designates the time limit in which a clear confirmation must be returned by the 
DCE (the PPSN) after a clear request has been issued by the DTE (the CyberSWITCH).