Appendix B: EPIM Specifications
Page B-4
MicroMMAC Installation Guide
The transmitter power levels and receive sensitivity levels listed in
Table B-1 represent Peak Power Levels after optical overshoot. You must
use a Peak Power Meter to correctly compare the above values to those
you measure on any particular port. If you measure Power Levels with an
Average Power Meter, you must add 3 dBm to the measurement to
correctly compare those measured values to the values listed above (e.g.,
-29.5 dBm peak = -32.5 dBm average).
Table B-1 represent Peak Power Levels after optical overshoot. You must
use a Peak Power Meter to correctly compare the above values to those
you measure on any particular port. If you measure Power Levels with an
Average Power Meter, you must add 3 dBm to the measurement to
correctly compare those measured values to the values listed above (e.g.,
-29.5 dBm peak = -32.5 dBm average).
Table B-2
EPIM-F3 Specifications
Parameter
Typical Value
Minimum
Maximum
Transmitter Peak
Wave Length
Wave Length
1300 nm
1270 nm
1330 nm
Spectral Width
60 nm
–
100 nm
Rise Time
3.0 ns
2.7 ns
5.0 ns
Fall Time
2.5 ns
2.2 ns
5.0 ns
Duty Cycle
50.1%
49.6%
50.7%
Bit Error Rate
Better than 10
-10