Output Solutions ez-2000plus Guide De Référence
Setup Commands
^An - Printing mode
Syntax
^An
Parameter
n = D, Direct thermal mode, the ribbon out sensor is disabled.
n = T, Thermal transfer mode, the ribbon out sensor is enabled.
n = T, Thermal transfer mode, the ribbon out sensor is enabled.
Description
Set the print mode
^Bx - Set the backward length
Syntax
^Bx
Parameter
x = 0~1000 (unit: mm)
Description
Set the backward length of the paper
^Cx - Number of copies per label
Syntax
^Cx
Parameter
x = 1 ~ 32767
Description
Set the number of copies to print for a label.
^D+dddd.hh - Date calculation function
Syntax
^D+dddd.hh
Parameter
dddd=days in 4 digits. Set how many days to be added to the current date.
hh= hours in 2 digits. Set how many hours to be added to the current time.
hh= hours in 2 digits. Set how many hours to be added to the current time.
Description
This command will set the specified days and hours forward based on the printer's current
date then print it.
date then print it.
Example
In this sample, the printer will print current time and
count the date that is 5 days and 12 hours after
current time.
^Q40,0,0
^W100
^AT
^L
Dy2-me-dd
Th:m:s
~D01,01,05,12,00,00
AD,72,96,1,1,0,0,Manufactured Date: ^D ^T
AD,72,190,1,1,0,0,Expiration Date: ^D+0005.12
E
count the date that is 5 days and 12 hours after
current time.
^Q40,0,0
^W100
^AT
^L
Dy2-me-dd
Th:m:s
~D01,01,05,12,00,00
AD,72,96,1,1,0,0,Manufactured Date: ^D ^T
AD,72,190,1,1,0,0,Expiration Date: ^D+0005.12
E
(current time of the printer)
Manufactured Date: 06-JAN-01 12:00
(5 days and 12 hours after current
time)
Expire Date: 06-JAN-07
^Dx - Number of labels per cut
Syntax
^Dx
Parameter
x = 0, disable the cutting.
x = 1 ~ 32767, number of label per cut.
x = 1 ~ 32767, number of label per cut.
Description
Number of labels per cut (refer to page35)
^Ex - Stop position setting
Syntax
^Ex
Parameter
x = 0~40 (unit: mm)
Description
Feed the paper to specific stop position.
5