Grandstream ht-502 Manuel D’Utilisation

Page de 32
 
Grandstream Networks, Inc. 
HT-502 User Manual 
Page 32 of 32  
 
Firmware 1.0.0.77 
Last Updated:  1/2008
 
 
R
ESTORE 
F
ACTORY 
D
EFAULT 
S
ETTING
 
WARNING!  
Restoring the Factory Default Setting will DELETE all configuration information of the phone. 
Please BACKUP or PRINT out all the settings before you approach to following steps.  Grandstream will 
not take any responsibility if you lose all the parameters of setting and cannot connect to your VoIP service 
provider. 
 
There are two ways to reset the device. 
 
Reset Via the Reset Button  
1.  Locate a needle-sized hole on the back panel of the HT502 unit next to the power connection. 
2.  Insert a pin in this hole, and press for about 7 seconds. The back LEDs for LAN and WAN will 
be solid on to indicate the reset. 
3.  Take out the pin.  All unit settings are restored to factory settings. 
 
Reset Via IVR 
1.  Find the MAC address of the device. It is a 12 digits HEX number located on the bottom of 
the unit. 
 
2.  Encode the MAC address. Please use the following mapping: 
0-9: 0-9 
A: 22 
B: 222 
C: 2222 
D: 33 
E: 333 
F: 3333 
For example, if the MAC address is 000b8200e395, encode the address as 
“0002228200333395”. 
 
3.  To perform factory reset: 
Pick up the headset and dial “***” for voice prompt. 
Enter “99” and get the voice prompt “Reset”. 
Enter the encoded MAC address of the device. 
Wait for 15 seconds. The device will reboot automatically and restore to factory 
default setting. 
 
NOTE: 
1.  Factory Reset will be disabled if the “Lock keypad update” is set to “Yes”. 
2.  Please be aware by default the HT502 WAN side HTTP access is disabled.  
3.  After a factory reset, the device’s web configuration page can be accessed only from its LAN port.