Monitors, reports
The Diamond Storage Array will function under 
normal external operating temperatures of 5°C 
and 40°C. Temperature sensors provide data to 
the software to trip a temperature warning alarm 
and will, at excessively high or low temperatures, 
disable disk drive activity to protect the drives. 
The Diamond reports the temperature via SES, 
CLI and the ExpressNAV interface as well as the 
state of the temperature warning alarm (N
ot 
Present, OK, Warning, Critical
). The temperature 
warning alarm will report OK during normal 
operating conditions.
In an abnormal operating condition, such as 
blower failure, under high ambient temperatures 
when the Diamond internal midplane temperature 
reaches 47°C, the temperature alarm will report 
Warning
 and activate the audible alarm and fault 
LED on the front of the unit. If the internal 
midplane temperature were to reach 52°C, the 
temperature warming alarm will report 
Critical
, the 
array will be taken off line, and all disk drive 
activity will be disabled. The exact external 
ambient conditions which the Array will be taken 
off line depends on data activity, but will occur 
between 38 and 42°C.
Power supply monitoring
The Diamond Storage Array monitors the 
operation of its power supplies and blower 
assemblies every 30 seconds. If the status 
changes, the system reports it visually with an 
LED and a message in the CLI. 
If a power supply or blower fails, the management 
system sends a CLI message and turns off the 
corresponding power supply LED. 
The blower assembly directly adjacent a power 
supply must be functioning properly for the power 
supply to work properly. If a blower assembly 
fails, the power supply will shut down and the 
management system will send a CLI message. 
The corresponding power supply LED on the 
system management card will also turn off. 
If a good replacement power supply or blower 
assembly is inserted into the array, the 
management system will send a CLI message and 
the corresponding system management card LED 
will go on. It may take up to 30 seconds for the 
system to note these changes.
System fault LED and error codes
If a serious hardware or software error occurs in 
the Diamond Storage Array, the System Fault 
LED will display a series of flashes or blink 
codes. Error information will be reported via the 
Command Line Interface if it is operational.
At power up, the green Diamond Array Ready 
(RDY) LED turns on after successful completion 
of the POST (Power On Self Test) indicating the 
array is available for normal operation. 
During operation, the Ready LED will stay lit 
even if the amber Fault (FLT) LED lights.
If a serious error occurs in the array, the amber 
Fault LED will flash repeatedly in a blink code 
pattern 
•  an initial series of blinks indicating the system 
problem
Exhibit 10.0-1  Typical Diamond Storage Array operation over a range of external ambient temperatures. Alarms 
will be audible, visual, CLI and SES cues as described above.
Temperature
Condition
25°C
blowers OK
25°C
1 blower fails
32°C
blowers OK
32°C
1 blower fails
35°C
blowers OK
35°C
1 blower fails
40°C
blowers OK
40°C
1 blower fails
Read/Writes
normal
normal
normal
normal
normal
normal
normal
Array offline
Alarms
OK
OK
OK
OK
OK
WARNING
OK
CRITICAL