Cleveland oeb-10.10 Guide De Spécification

Page de 1
Cleveland
Project  ________________________________
Item  __________________________________
Quantity _______________________________  
FCSI Section ____________________________
Approval  _______________________________
Date  __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110 
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com  
 
COMBI OVEN-STEAMER
Stacking Kits for Electric Table Type Models
(OEB 6.10 on OEB 10.10 or OES 6.10 on OES 10.10)
SECT.
IIB
PAGE
5H
0108
Model #
Description
CSTK-1010
for mounting one 6.10 model on top of one 10.10 model
CSTK-1010CA
for mounting one 6.10 model on top of one 10.10 model (with casters)
UNIT A
UNIT B
RC
CS
W1
W2
D
RC
CS
W1
W2
D
37.83"
NOTE: Overall height of unit does not change for units with casters.
LEFT SIDE VIEW
UNIT A
UNIT B
4.38"
48.54"
7
8
.4
1
"
36.70"
1.58"
1.82"
2
8
.4
3
5.00"
3
8
.9
8
"
6.00
"
8
0
.0
0
(M
IN
.H
O
O
D
R
E
Q
U
IR
E
M
E
N
T
)
2.52"
UTILITIES
(Utility connection shown below are listed per unit)
Required Clearances:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to
the unit.
• Allow for sufficient clearance on left side for service access (contact the factory
service department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
Do not connect to a G.F.I. outlet.
BOILER
UNIT A - OEB-6.10
UNIT B - OEB-10.10
MODELS
208/3/60 240/3/60
440/3/60 480/3/60
208/3/60 240/3/60 440/3/60 480/3/60
Total Connected Load:
9.9 KW
12.8 KW
11 KW
13.1 KW
16.4 KW 21.6 KW
18.5 KW 22 KW
Hot Air:
8.6 KW
11.4 KW
9.1 KW
10.2 KW
14.7 KW 19.6 KW
16.5 KW 19.6 KW
Steam Generator:
7.7 KW
10.2 KW
8.6 KW
10.2 KW
12.8 KW 17.1 KW
14.3 KW 17.1 KW
Amps per Phase:
27.3
30.8
15.2
16.3
45.5
51.8
24.2
26.4
BOILERLESS
UNIT A - OES-6.10
UNIT B - OES-10.10
MODELS
208/3/60 240/3/60
440/3/60 480/3/60
208/3/60 240/3/60 440/3/60 480/3/60
Total Connected Load:
9.9 KW
12.8 KW
11 KW
13.1 KW
16.4 KW 21.6 KW
18.5 KW 22 KW
Hot Air:
8.6 KW
11.4 KW
9.1 KW
10.2 KW
14.7 KW 19.6 KW
16.5 KW 19.6 KW
Amps per Phase:
27.3
30.8
15.2
16.3
45.5
51.8
24.2
26.4
Water Connections:
Cold Water (drinking water quality)
Flow Pressure:
30 - 60 PSI
Water Inlets:
3/4" GHT-F (Female Garden Hose
Connection)
Treated Water for Steam Generator
Untreated Water for Condenser
Drain Connection:
2" Tube
Venting:
Exhaust Hood required
*Connection for Cleaning Solution
*Connection for Rinse Cycle
*Available as an option
Note: For additional connection details,
see spec sheet for each individual
combi model to be stacked.
D
RC
CS
W1
W2