Error Messages and Remedies 
Error 
Message on display 
Possible cause 
Remedy 
Water tap closed 
Open water tap 
Solenoid valve dirt filter  
contaminated 
Remove and clean filter 
E01 Not 
enough 
water 
Solenoid valve fault 
Call customer service 
E02 Connection 
area 
temperature too high 
Connection area ventilation fault,  
air supply blocked 
Allow Combi to cool, or continue 
cooking at a lower oven 
temperature, and call customer 
service 
Motor temperature monitor triggered, 
external failsafe triggered 
Call customer service 
E03 Fan 
malfunction 
Fan motor fault 
Call customer service 
E04 Connection 
area 
fan 
malfunction 
Auxiliary fan fault 
Call customer service 
E05 
no gas 
Gas supply interrupted 
Open gas tap 
Excess oven temperature 
Call customer service 
E11/E21 
Excess temp. in oven/oven 
sensor failure 
Oven sensor fault 
Call customer service 
E13/E23 
Excess temp. of steam 
generator/steam gen. 
sensor failure 
Steam generator sensor fault 
Call customer service 
Water tap closed 
Open water tap 
Excess temperature in condenser via 
hot water connection 
Connect Combi to cold water, 
restart 
Solenoid valve dirt filter contaminated 
Remove and clean filter 
Solenoid valve fault 
Call customer service 
E15/E25 
Excess temp. of condenser 
/ condenser sensor failure 
Condenser sensor fault 
Call customer service 
E22 
Core temperature sensor 
fault 
Core temperature sensor fault 
Set cooking program with time, 
call customer service 
E24 
Bypass sensor failure 
Bypass sensor fault 
Call customer service 
E26 
Steam generator safety 
temp. limiter sensor failure 
Safety temp. limiter sensor fault in 
steam generator 
Call customer service 
E27 
Excess temperature of 
Steam Generator heater 
Steam generator dirtied 
Descale steam generator 
E29 Ground 
connection 
of 
sensor 
Temperature sensor fault 
Call customer service 
E33 
Steam generator heater 
error 
Steam generator heater fault 
Call customer service 
E34 
Steam generator pump 
error 
Steam generator pump fault 
Call customer service 
E80/E95/E96 
ID error / software error / 
connection fault 
Control fault 
Call customer service 
E82 
Working parameter error 
Problems during switch between °C / 
Check settings in Cookbook, or 
check °C/F in Settings 
Cleaner canister or nozzle rinsing fluid 
agent empty 
Fill canister 
Low agent 
pressure! 
No cleaner pressure 
Pump fault 