Cleveland oeb-10.10 Manuel D’Utilisation
F
E
D
C
B
A
1
2
3
4
5
6
7
8
F
E
D
C
B
A
1
2
3
4
5
6
7
8
CLEVELAND RANGE, LLC
1333 East 179th St., Cleveland, Ohio 44110-2574
VOLTAGE:
WATTAGE:
CURRENT:
WATTAGE:
CURRENT:
DATE
SHEET OF
REV
DRAWN BY
DRAWING NO.
THIS DESIGN DESCRIBES A PROPRIETARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE.
THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF CLEVELAND RANGE.
TITLE
SIZE
B
WIRING DIAGRAM
OEB 6.20/10.10
300491
3Ø 208-240
15.8-20.7KW
45.5-51.8A
15.8-20.7KW
45.5-51.8A
DRL
6-24-05
5
7
B
M
M
BM 5010
-M3.1
-Y1
-F2.1
-A13
-X10
-M4
-X10
-X10
-S7
-S2
-X10
-B
8
-Y10
-Y20
-Y22
-Y23
-A11
-X10:20
/2.E1
-X10:D
C8
/2.E1
-X10:20
/2.B8
-K0:A1
/3.C3
-X10:31
/3
.D
2
-G
1:
12V
/3
.D
2
-G1
:0
V
/4
.F
4
-x1
3:
1
/3
.C
4
-K5
:2
1
/3
.C
6
-K
56:
21
/2
.D
5
-K
44:
22
-K5
0:
21
-K5
7:
21
-K4
4:
A
1
/3
.C
3
-X
10:
31
/2
.D
7
-K2
:2
1
-K4
:2
1
RD 18
RD 18
RD 18
RD 18
RD 18
RD 18
RD 18
BU 18
BU 18
RD 18
RD 18
RD 18
RD 18
A
B
C
D
B
C
D
RD
1
8
RD
1
8
RD
1
8
BU 18
RD
1
8
RD
1
8
RD
1
8
RD
1
8
RD
1
8
GN
/B
U
BK
WH
BU
RD
3
1 2
4
GN
/R
D
GN
GN
GN
WH
YL
RD
YL
RD
YL
RD
YL
RD
YL
RD
-B
4
-B
3
-B
5
-B
6
-B1
0
RD
BU
P>
L
H
-B
1
RD
1
8
PR
OBE C
O
N
D
E
N
S
E
R
PR
OBE BYPAS
S
PR
OBE OV
E
N
W
A
TER
L
EVEL
P
R
O
B
E
DOOR MAGNET SWITCH
14
13
13
14
15
7
15
6
13
3
13
4
13
6
NL
L
N
L
N
A2
A1
A1
A2
A1
A2
A1
A2
L
N
RD
1
8
RD
1
8
RD
1
8
KTM
CT
C
OPERATION MODULE
X39: 1
RD 18
RD
BK
21
X1
X2
22
21
AUX. FAN
OVEN LAMP
CONDENSER
DEHUMIDIFICATION
STEAM GENERATOR
FILLING
FILLING
WATER CLEANING
RINSING AGENT
CLEANING AGENT
CLEANING AGENT
STEAM GENERATOR
PUMP
PUMP
IDENTIFICATION MODULE
1A
CABLE CONNECTION SM ON BM
CONTROL 500
CONTROL 500
1
∼
-H5.1
FBS2-6
1
∼
PE
-X10
100
-Y2
-Y3
-Y21
/4
.D
2
-Q
57
:1
4
/3
.C
4
/3
.C
5
/2
.D
7
/2
.D
5
-X10:21
F2
PE
JUMPER
L2
-W1
(OPTION)
-A12
PICTO
MODULE
-Q57:14
/4E.2
/3.B6
-K10:8
(TEMP PR
OBE
)
STEAM GEN
E
R
A
T
O
R
OVER
TEMPER
AT
URE
STEAM GEN.
EL
EMEN
T (PR
O
B
E
)
10
3
-A10
X18:
1
3
1
X19:
CONTROL BOARD
SM 5010
10 9 8
X17:
7 6 5 4
1 2
2 1
12 11
X14:
PUMP/CLEANING AGENT
COMPARTMENT RINSE VALVE
STEAM GEN OVER TEMP
STEAM GEN PUMP
9
H
O
T
AI
R
(INNE
R)
12
4 5 6 7 8 9
11
10
9 8
X16:
7 6
3
5 4
2 1
MOTOR
OVER
T
E
M
P
MOTOR
OVER
T
E
M
P
M
O
T
O
R
/
RIGHT
MOTOR
/
LE
F
T
M
O
T
O
R
/ FAST
MOTOR
/
S
LO
W
1 2 3 4
X11:
5 6
14 13 12 11 10
HOT A
IR (
O
U
T
E
R
)
L1-
2O8/24
0-
IN
P
U
T
STEAM GE
N
8
7
STEAM GE
N
OVEN
L
A
M
P
1 2 3 4
X12:
7
X15:
8
6 5 4 3
2 1
X13:
DEHUMIDICATION
/V
A
LV
E
CONDE
NS
OR/
V
A
LV
E
GEM FILL/VA
LV
E
5 6 7
8
9
10
6
7
PUMP/RINSE
2
1
1
4
3
3
5
4
5
2
3
9
7
6
6
8
1
10
X10:
Rx
D
12V
DC+
F
A
N
12V
DC-
F
A
N
12V
D
C
IN
0V
DC
IN
GN
D
ID
M (W
)
ID
M (B
L)
IDM (
R
)
ID
M (BL
K
)
R
ESE
T
Tx
D
0V
D
C
0V
D
C
+5
V
D
C
+5
V
D
C
CLEANING OPTION ONLY
WIRING DIAGRAM
CLEANING PRESSURE SWITCH
CLEANING OPTION ONLY
-X10
74