◊  In the light and medium modes (one and two drops in the display) the Y2
valve will be energized until the bypass probe (B5) is satisfied.
◊  In the full mode (3 drops in the display) the Y2 valve will be energized
continuously.
g
  When the timer counts to 0 or the core temp probe (B10) reaches the set amount
the cycle ends. 
7
  With the combi in the Rethermalization mode with time on the timer, the door closed
and the start switch is depressed
a
  The front display will include a lighted bar under the Rethermalization symbol
•  When the heat circuit is energized the heat symbol will be energized
•  The cooking mode symbol will be energized.
•  The time display will invert and begin to count down.
b
  The fan circuit is energized
•  If the combi fan is in the normal setting 220 VAC is sent from terminal 5 on
connector X11 through the normally closed auxiliary contacts of contactor
K57 to the coils of contactors K55 and K56
◊  The K55 and K56 contactors close sending 220 VAC through the Q56
overload to the motor and the motor turns at a high speed.
◊  The normally closed auxiliary contacts of both K55 and K56 open
preventing the K57 contactor from energizing.
•  If the combi fan is in the reduced setting 220 VAC is sent from terminal 6 on
connector X11 through the normally closed auxiliary contacts of contactors
K55 and K56 to the coil of contactor K57
◊  The K57 contactor closes Sending 220 VAC through the Q57 thermal
overload to the motor and the motor turns at a reduced speed.
◊  The normally closed auxiliary contacts of K57 open preventing the K55
and K56 contactors from energizing.
•  For the first 2 minutes 220 VAC is sent from terminal 4 on connector X11
through the normally closed auxiliary contacts of contactor K5 to the K50
contactor coil 
◊  K50 contactor closes and the motor turns CW
◊  The normally closed auxiliary contacts on K50 open preventing the K5
contactor from energizing.
•  For 15 seconds the motor is de-energized and allowed to coast.
•  For the next 2 minutes 220 VAC is sent from terminal 3 on connector X11
through the normally closed auxiliary contacts of contactor K50 to the K5
contactor coil 
◊  K5 contactor closes and the motor turns CCW
◊  The normally closed auxiliary contacts on K5 open preventing the K50
contactor from energizing.
•  NOTE: If the door switch (S7) opens by the door opening, then the fan circuit
is de-energized.  Then the motor will be pulsed in the opposite direction to
“break” the fan.  This is to stop the fan quicker for the operator.
c
  The hot air heat circuit is energized 