Cleveland ogb-10.10 Manuel Complémentaire

Page de 101
  The Hot Air Burner Control Module (N20) senses at least 1.5 micro amps
DC from the flame sensor (P1) at terminal 3 of connector X2 and sends a
signal from terminal 2 of connector X1 to terminal 12 of connector X15
on the Control Board (A10)
  The heat circuit will remain energized until the cabinet set temperature is
reached as sensed at probe B6.
e
  The steam circuit is energized. 
  120 VAC is sent from terminal 4 of connector X12 on the Control Board
(A10) to the coil of the Y3 solenoid allowing water to be thrown against the
element until the bypass probe (B5) senses 183 degrees F.
  The heat circuit will remain energized until the cabinet set temperature is
reached
f
  If the bypass probe (B5) drops below the set level the steam circuit will start again
g
  When the condensate box is heated to 140 degrees F at the B3probe, 120 VAC is
sent from terminal 5 of connector X12 to the condenser valve (Y1) until the
temperature drops.
h
  When the timer counts to 0 or the core temp probe (B10) reaches the set amount
the cycle ends and the steam generator reverts to the standby temperature of 190-
degree F.
88