Hussmann p1x-e Fiche De Données

Page de 5
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H. 
P1X-E
Discharge Air (°F)
31
Evaporator (°F)
24
Unit Sizing (°F)
22
Btu/hr/ft*
P1X-E
Parallel
520
Conventional
555
*For all refrigeration equipment other than
Hussmann, use conventional Btu values.
DEFROST DATA
P1X-E
Frequency (hr)
8
Defrost Water (lb/ft/day)
4
(± 15% based on case configuration and
product loading).
O
FF
T
IME
P1X-E
Temp Term (°F)
43°F
Failsafe (minutes)
35
E
LECTRIC OR
G
AS
Not Recommended 
Standard Defrost Thermostat 
Close on rise: close 43°F  —  open 33°F 
CONVENTIONAL CONTROLS
Low Pressure Backup Control
P1X-E
CI/CO**
17°F / 7°F
Indoor Unit Only, Pressure Defrost
Termination**
48°F
**Use a Temperature Pressure Chart to
determine PSIG conversions.
Estimated Charge (lb)***
P1X-E
4 ft 
0.9
6 ft 
1.2
8 ft 
1.7
12 ft 
2.3
***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
3 of 5
P/N 0475057_B
HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM
43 
1
/
8 
(1095)
31 
5
/
(804)
3
/
4  
(120)
30 
1
/
4   
(768)
42 
 
(1064)
33 
1
/
(851)
26 
1
/
(665)
Electrical 
Case to Case 
Connections
FAN
L
3 In. 
(77 mm) 
Required 
Air Gap
Refrigeration 
Outlet
28 
5
/
8 
(727)
31
 
(787)
15
 
(381)
17 
1
/
(436)
16 
1
/
(413)
7
/
8  
(175)
3
/
(246)
30 
1
/
4   
(766)
1
/
(54)
12 
7
/
(327)
1
/
(130)
Dimensions shown as inches and (mm).
Single Deck, 1 Display Level
Impact  
Excel
P1X-E
Bulk Produce
P1X-E
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.