Aethra d2061 Manuel D’Utilisation

Page de 122
USER’S MANUAL 
                                                                                ADSL TESTER D2061 
 
•  Incoming 64k all bear: the instrument waits for a call from a remote device. 
As soon as a call is received, the instrument answers automatically and 
starts to generate the PRBS and measure the BER according to the set 
pseudorandom sequence. 
 
In ‘Incoming 64k all bear’, the test equipment can be used as an 
automatic answer remote machine, which activates every kind of 
incoming call an performs a BER test with generation and 
measure of the PRBS sequence. 
Bit Sequence:  Set the pseudo-random bit sequence to be used from the list or 
define your own pattern.   
Pass/Fail Test: Choose the BER value. This value is used to determine the pass or 
fail test condition. Use E-7 (10-7) when no other value is requested. The G.821 value 
calculates the acceptability threshold according to the performance target expected 
by the G.821 recommendation. The HRX(%) parameter modifies such threshold.     
Error Injection: Insert the number of errored bits which the device sends on line. It is 
possible to use both manual and automatic mode. In automatic mode, you need to 
insert the BER value to be sent. 
SES Threshold:  Choose the number of errors per second in order to consider the 
second as Severely Errored. Use the G.821 default value, corresponding at 10-3 
when no specific value is requested.   
DM Threshold: Choose the number of errors per minute in order to consider the 
minute ad Degraded. Use the G.821 default value when no specific value is 
requested. In the last G.821 recommendation issue, DM result has been cancelled 
from the recommendation but, the device implements the DM measure anyway. 
HRX(%): Enter the variation percentage for the acceptability threshold according to 
the type of call (e.g. National or International).   
If test fails then: Select the action to be taken by the device in case of threshold 
acceptability overcoming. You can choose between maintaining the connection 
active, disconnecting it, or continuing the test in progress even in case of threshold 
acceptability overcoming. Used for call routing search.     
Auto print: Select the autoprint condition in order to send the test results over RS232 
serial port, e.g. to download them to a PC.   
•  time interval: 15 or 30 minutes 
•  DM: when the DM threshold value is overcame 
•  End of cycle: results are printed every cycle ending 
CHAPTER 3 - PERFORMING A MANUAL TEST 
61