Symbol Barcodes - Scanner Parameters – SE Barcode Type Specific 
151 
E-SW-SCANNERPG-L 
 
Integrated Scanner Programming Guide 
Convert GS1 DataBar (RSS) to 
UPC/EAN 
Scanner:  
955 
 
Parameter Default Value: 
Disable 
This parameter only applies to GS1 DataBar Omnidirectional (RSS-14) and GS1 DataBar Limited 
(RSS Limited) symbols. When this conversion is enabled, GS1 DataBar Omnidirectional (RSS-14) 
and GS1 DataBar Limited (RSS Limited) symbols encoding a single zero as the first digit have the 
leading ‘010’ stripped and the barcode reported as EAN-13. 
Barcodes beginning with two or more zeros but not six zeros have the leading ‘0100’ stripped and the 
barcode reported as UPC-A. The UPC-A Preamble parameter to transmit the system character and 
country code applies to converted barcodes. Note that neither the system character nor the check digit 
can be stripped. 
Enable Convert GS1 
DataBar (RSS) to 
UPC/EAN 
Enable 
 
 
 
Disable Convert GS1 
DataBar (RSS) to 
UPC/EAN 
Disable