Electrovoice cp3000s Mode D'Emploi

Page de 36
FRONT PANEL
This indicator lights when the power amplifi er has been switched on. Causes for  
the POWER-indicator not lighting are: the appliance is not connected to the mains  
network or a defective primary fuse. 
The PROTECT LED lights indicating that one of the internal protection circuits    
against thermal overload, short-circuit, Back-EMF, HF-occurrence at the output,  
etc., has been activated. The output relays interrupt the connected loads from    
 
the power amps while input signals are interrupted as well, preventing the connected  
 
loudspeaker systems and the power amplifi er itself from being damaged.    
 
Whatever caused the fault – e.g. a short-circuited speaker cable – needs to be 
remedied. In case of thermal overload you have to wait until the power amplifi er 
automatically regains normal operation.
The SIGNAL LED lights as soon as an audio signal of approximately 30dB below full  
modulation is present at the output. The LED is dimmed when speaker cables are  
short-circuited or a protection circuit has been activated.
The 0dB LED lights whenever the power amplifi er is driven at its limits. Higher input  
voltage does not result in higher peak output voltage. In addition, the 0dB indicator  
comes in handy when adjusting external limiters.
This indicator lights as soon as the integrated dynamic audio signal limiter is  
 
activated and the power amplifi er is driven at the clipping limit or generally  
 
at its maximum capacity. Short-term blinking is not a problem, because the internal  
 
limiter trims input levels of up to +21dBu down to an S/N-ratio of approximately 1%.  
 
If, on the other hand, this LED lights constantly, reducing the volume is 
 
recommended to prevent the loudspeaker systems connected from being damaged  
 
by probable overload.
Detent potentiometers scaled in dB (steps of 1dB) for 
adjusting the power amp’s overall amplifi cation. To prevent  
distortion in mixing consoles connected to the amp, setting  
these controls to a value between 0dB and -6dB is generally  
recommended. The dB-scale provides direct indication of the  
control attenuation applied to the fi xed internal amplifi cation.
Use the POWER switch located on the front panel to power-on the appliance. The soft-start function 
protects against current inrush peaks on the mains, which in addition prevents the mains line protection 
switch from activating during power-on. The loudspeaker outputs are activated via relay switching with 
a delay of approximately 3 seconds to effi ciently attenuate eventual power-on noise. The PROTECT 
LED lights during the delay time. This is normal, confi rming the immaculate operation of the protection 
circuitry. 
6