Main Points of Operation
Anti-cold Blowing Off
In heating mode,the indoor fan will not run
immediately after the unit starts up, which will the
cold air being blow out.
Defrosting Function
In heating mode, when frost is formed on the outdoor heat
exchanger, the air conditioner will automatically defrost for
few minutes. During defrosting, both indoor fan and outdoor
fan will stop running. When defrosting finishes, air condi-
tioner will automatically be back to running.
Hints
The air conditioner absorbs heat form outdoor and
releases to indoor when in heating mode, therefore the
outdoor environmental temperature will affect heating
efficiency.
Auto-restant function(to be applied for a necessary situation):
After the auto-restant function is set, if power failure suddenly occurs while the air
conditioner is working,it will resume the previous working state when the power is supplied
again.
Setting Method: When the remote controller is on (excluding timer mode and fan mode),press
                          the ìSLEEPî button on the remote controller 10 times within 5 seconds,and
                          after the buzzer sounds 4 times, the air conditioner will enter the state of auto-
                          restant function
Cancel Method:Press the ìSLEEPî button on the remote controller 10 times within 5 seconds,
                         and after the buzzer sounds 2 times, the auto-restant function will be
                         cancelled.
Note: When a power failure suddenly occurs during the air conditioner is working after the
      auto-restant function is set,if the air conditioner will not be used for a long
         time, please shut off the power supply to prevent its operation from being resumed
          after the power is supplied again, or press the ì ON/OFF î button after the power come
          again.
Defrosting Running
Wait a
minute